background image

ZANUSSI

P R O F E S S I O N A L

ACTIVE BLAST CHILLER / FREEZERS

120-180 KG 20 GN 2/1

110026

1 SINGLE-SENSOR
PROBE-BL.C/FREEZERS LW

1

1

1

1

1

1

1

INCLUDED ACCESSORIES

Disassembled

l

l

Power supply - V, phases, Hz

400 V, 3N,

50

400 V, 3N,

50

400 V, 3N,

50

400 V, 3N,

50

400 V, 3N,

50

400 V, 3N,

50

400 V, 3N,

50

Net weight - kg.

300

180

605

438

605

438

438

    installed-electric

6.515

6.3

8.335

1.735

8.335

1.735

1.735

Power - kW

    at evaporation temperature - °C

-30

-10

-10

-10

-10

-10

Refrigerant power

Refrigeration power - W

4260

20200

20200

20200

20200

20200

Refrigerant type

R404a

R404a

R404a

R404a

R404a

R404a

R404a

N° defrost in 24 hrs.

3

3/25'

3/30'

3/30'

3/30'

3/30'

3/30'

Compressor power - HP

4

7,5; 

7,5; 

Max load capacity - trays h 65 mm - n°

20

20

20

20

20

Trays type

600x400;

GN 2/1

600x400;

GN 2/1

600x400;

GN 2/1

600x400;

GN 2/1

600x400;

GN 2/1

600x400;

GN 2/1

600x400;

GN 2/1

Door hinges

Right Side

Right Side

Right Side

Right Side

Right Side

Right Side

Right Side

N° and type of door

1

1

1; 

1; 

1; 

1; 

2; 

    height

1850

1850

1850

1850

1850

1850

1850

    depth

920

920

946

946

946

946

946

    width

772

772

752

752

752

752

752

Internal dimensions - mm

    height

2470

2230

2470

2230

2470

2230

2230

    depth/with open doors

1285, 2099

1285, 2099

1285, 2099

1285, 2099

1285, 2099

1285, 2099

1285, 2099

    width

1400

1400

1400

1400

1400

1400

1400

External dimensions - mm

Cooling unit

Built-In

Remote

Built-In

Remote

Built-In

Remote

Remote

    UK Guide lines - chilling / freezing

120, 100

120, 100

180, 170

180, 170

180, 170

180, 170

180, 170

    NF Regulations - chilling / freezing

144, 144

144, 144

144, 144

144, 144

144, 144

Productivity per cycle - kg.

BCF120A

110091

BCF120RA

110092

BCF180A

110026

BCF180RA

110028

BCF180DA

110027

BCF180RDA

110029

BCF180RPA

110030

CHARACTERISTICS

MODELS

TECHNICAL DATA

RANGE 
COMPOSITION

Chilling means bringing the temperature of 
cooked food from +90ºC to +3°C in a short 
time lap to minimize bacteria proliferation and 
avoid loss of food consistency and texture. 
The ZANUSSI easyChill Blast 
Chillers/Freezers reduce temperature to 
+3°C at food core in less than 90 minutes 
and down to -18°C in less than four hours. 
After the Blast Chilling a holding cycle starts 
automatically to respectively maintain food at 
+3°C and -18°C. Blast freezed food has a 
solid 6 months/1 year shelf life without loss of 
flavour, nutritional values and weight. The 
opportunity to prepare in a single shot the 
food to be used in different times during the 
week enables a better work scheduling and 
therefore a sensible reduction in labour costs.

FUNCTIONAL AND 
CONSTRUCTION 
FEATURES

 

Soft Chilling (Air temperature 

–2°C). 

 

Hard Chilling (Air temperature 

–20°C). 

 

All the probe-driven cycles feature 

ARTE (Algorithm for Remaining 
Time Estimation): the machine 
displays the actual time needed to 
end the cycle and to make planning 
the activities easier. 

 

Holding at +3°C (automatically 

activated at the end of each cycle). 

 

Turbo cooling: the chiller works 

continuously at the desired 
temperature. Ideal for continuous 
production and for pastry application. 

 

Automatic recognition of the 

insertion of the food probe (cycles 
piloted either by food probe 
temperature or by time)

 

Single sensor core probe as 

standard.

Summary of Contents for 110026

Page 1: ...170 NF Regulations chilling freezing 144 144 144 144 144 144 144 144 144 144 Productivity per cycle kg BCF120A 110091 BCF120RA 110092 BCF180A 110026 BCF180RA 110028 BCF180DA 110027 BCF180RDA 110029 BCF180RPA 110030 CHARACTERISTICS MODELS TECHNICAL DATA RANGE COMPOSITION Chilling means bringing the temperature of cooked food from 90ºC to 3 C in a short time lap to minimize bacteria proliferation an...

Page 2: ...13 880213 880213 880213 BCF120A 110091 BCF120RA 110092 BCF180A 110026 BCF180RA 110028 BCF180DA 110027 BCF180RDA 110029 BCF180RPA 110030 ACCESSORIES MODELS OPTIONAL ACCESSORIES The control unit provides several operating settings time core temperature according to NF and UK regulations time air temperature probe personalised according to national regulations sterilizing cycle UV lamps built in on r...

Page 3: ...ns without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L WOC Cooling water outlet l l l Q Appliance lifting connection l l EI Electrical connection 400 V 3N 50 400 V 3N 50 400 V 3N 50 D Water drain 3 4 3 4 CWI Cold water inlet 1 1 BCF120A 110091 BCF180A 110026 BCF180DA 110027 LEGEND 110091 110027 110026 ...

Page 4: ...ior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L RI Remote refrigeration connection l l l Q Appliance lifting connection l l EI Electrical connection 400 V 3N 50 400 V 3N 50 400 V 3N 50 ED Remote electrical connection l l l D Water drain 3 4 3 4 BCF120RA 110092 BCF180RA 110028 BCF180RDA 110029 LEGEND 110092 110029 110028 ...

Page 5: ... alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L RI Remote refrigeration connection l Q Appliance lifting connection l EI Electrical connection 400 V 3N 50 ED Remote electrical connection l D Water drain 3 4 BCF180RPA 110030 LEGEND 110030 ...

Reviews: