background image

ZANUSSI

P R O F E S S I O N A L

ACTIVE BLAST CHILLERS

10/15/28 kg

110718

1 SINGLE-SENSOR
PROBE-BL.C/FREEZERS LW

1

1

INCLUDED ACCESSORIES

Power supply - V, phases, Hz

230 V, 1N, 50 230 V, 1N, 50 230 V, 1N, 50

Net weight - kg.

88

95

124

Noise level - dBA

56

62

66

    installed-electric

0.51

0.715

1.096

Power - kW

    at evaporation temperature - °C

7.3

-5

-5

Refrigerant power

Refrigeration power - W

980

707

1436

Refrigerant quantity - g.

1100

1100

1530

Refrigerant type

R134a

R134a

R134a

N° defrost in 24 hrs.

4/30'

4/30'

6

Compressor power - HP

1/4

3/8

3/4

Max load capacity - trays h 65 mm - n°

3

3

6

Trays type

600x400; GN

1/1

GN 1/1;

600x400

GN 1/1;

600x400

Door hinges

Right Side

Right Side

Right Side

N° and type of door

1

1

1

    height

380

400

730

    depth

400

419

419

    width

640

641

640

Internal dimensions - mm

    height

850

970

1640

    depth/with open doors

700, 1407

760, 1500

760, 1500

    width

762

760

760

External dimensions - mm

Cooling unit

Built-In

Built-In

Built-In

Gross capacity (D.I.N. 8952) - l.

72

115

210

    UK Guide lines - chilling / freezing

10

15.2

28

    NF Regulations - chilling / freezing

7.2

10.8

21.6

Productivity per cycle - kg.

Power supply

Electric

Electric

Electric

BC10A

110780

BC15A

110717

BC28A

110718

CHARACTERISTICS

MODELS

TECHNICAL DATA

RANGE 
COMPOSITION

Chilling means bringing the temperature of 
cooked food from +90ºC to +3°C in a short 
time lap to minimize bacteria proliferation and 
avoid loss of food consistency and texture. 
The ZANUSSI easyChill Blast Chillers reduce 
temperature to +3°C at food core in less than 
90 minutes. After the Blast Chilling a holding 
cycle starts automatically to maintain food at 
+3°C. Blast chilled food has a solid 5 days 
shelf life without loss of flavour, nutritional 
values and weight. The opportunity to 
prepare in a single shot the food to be used 
in different times during the week enables a 
better work scheduling and therefore a 
sensible reduction in labour costs.

FUNCTIONAL AND 
CONSTRUCTION 
FEATURES

 

Soft Chilling (Air temperature 

–2°C). 

 

Hard Chilling (Air temperature 

–12°C). 

 

All the probe-driven cycles feature 

ARTE (Algorithm for Remaining 
Time Estimation): the machine 
displays the actual time needed to 
end the cycle and to make planning 
the activities easier. 

 

Holding at +3°C (automatically 

activated at the end of each cycle). 

 

Turbo cooling: the chiller works 

continuously at the desired 
temperature. Ideal for continuous 
production and for pastry application. 

 

Automatic recognition of the 

insertion of the food probe (cycles 
piloted either by food probe 
temperature or by time)

 

Single sensor core probe as 

standard (except for code 110780).

  

Summary of Contents for 110717

Page 1: ...ERISTICS MODELS TECHNICAL DATA RANGE COMPOSITION Chilling means bringing the temperature of cooked food from 90ºC to 3 C in a short time lap to minimize bacteria proliferation and avoid loss of food consistency and texture The ZANUSSI easyChill Blast Chillers reduce temperature to 3 C at food core in less than 90 minutes After the Blast Chilling a holding cycle starts automatically to maintain foo...

Page 2: ...nd manual defrosting All parameters are programmable The control unit provides two large displays to read out time core temperature residual time alarms service information Two customizable cycles for each operating modes allowing setting time and air temperature These two programs P1 P2 can be converted into ice cream specialist cycles shape maintenance and holding All information related to the ...

Page 3: ...8 kg DCA01 2010 05 28 The Company reserves the right to alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L EI Electrical connection 230 V 1N 50 BC10A 110780 LEGEND 110780 ...

Page 4: ...8 kg DCA01 2010 05 28 The Company reserves the right to alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L EI Electrical connection 230 V 1N 50 BC15A 110717 LEGEND 110717 ...

Page 5: ...8 kg DCA01 2010 05 28 The Company reserves the right to alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L EI Electrical connection 230 V 1N 50 BC28A 110718 LEGEND 110718 ...

Reviews: