background image

ACTIVE BLAST CHILLER / FREEZERS

7/15/28 KG.

DCB01

2011-06-10

The Company reserves the right to alter technical specifications without prior notice.

www.zanussiprofessional.com

ZANUSSI

P R O F E S S I O N A L

TROLLEY FOR 10XGN1/1 ROLL IN RACK

922130

TROLLEY FOR 10X1/1 & 2/1 ROLL IN RACK

922128

ROLL-IN RACK SUPPORT BC+BCF 28KG 10GN1/1

881518

RILSAN COATED GRID

881061

881061

881061

PRINTER HACCP BASIC VERS-REF.ELECR.CONTR

881532

881532

881532

PLASTIC COATED GRID-600X400 MM

880864

880864

880864

PAIR OF 1/1 GN AISI 304 S/S GRIDS

921101

921101

921101

KIT TO CONVERT TO 10X1/1 SLIDE-IN RACK

922201

KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW

880183

880183

COOK&CHILL KIT-6 GN OVEN/15KG BL.CHILLER

881528

80 MM PITCH SIDE HANGERS 10X1/1 GAS 0VEN

922116

80 MM PITCH SIDE HANGERS 10X1/1 ELE.OVEN

922115

60 MM PITCH SIDE HANGERS 10X1/1 GAS OVEN

922122

60 MM PITCH SIDE HANGERS 10X1/1 ELE.OVEN

922121

4 WHEELS FOR BLAST CHILLERS

881097

881097

4 FEET FOR UNDERCOUNTER BLAST CHILLER

881493

3-POINT-SENSOR PROBE-BL.C/FREEZERS LW

880212

880212

880212

1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW

880213

880213

880213

BCF7A

110781

BCF15A

110721

BCF28A

110722

ACCESSORIES

MODELS

OPTIONAL ACCESSORIES

 

The control unit provides several 

operating settings: time/core 
temperature according to NF and UK 
regulations, time/air 
temperature/probe personalised 
according to national regulations, 
sterilizing cycle: UV lamps built-in 
(on request), 3 single sensor or 
3-sensor temperature probes (as 
accessory), ideal for meats, 
automatic defrosting and manual 
defrosting. All parameters are 
programmable.

 

The control unit provides two large 

displays to read out: time, core 
temperature, residual time, alarms, 
service information. 

 

Two customizable cycles for each 

operating modes, allowing setting 
time and air temperature. These two 
programs (P1-P2) can be converted 
into ice-cream specialist cycles 
(shape maintenance and holding).   

 

All information related to the 

different operating models are 
recorded: date, time, cycle, core 

temperature, holding temperature, 
HACCP accordance. 

 

 An audible alarm starts when the 

cycle ends or terminates abnormally. 

 

Chilling times can vary according 

to food quantity, density, moisture 
contents and type of containers.

 

Internal and external finishing in 

304 AISI stainless steel and 
backpanel in galvanized steel. 

 

HCFC, CFC and HFC free 

insulation (Cyclopentane), HCFC 
and CFC free refrigerant gas 
(R404a).

 

Developed and produced in ISO 

9001 and ISO 14001 certified 
factory. 

 

Inner cell with rounded corners.   

 

Door equipped with removable 

magnetic gasket with hygienic 
design. 

 

Evaporator with antirust 

protection. 

 

Ventilator swinging panel foreasy 

access to the evaporator.  

 

Automatic heated door frame. 

 

Hot gas defrosting system.

 

Thermostatic expansion valve to 

optimize the cooling unit efficiency.  

 

Adjustable feet 150 mm high 

(except for code 110781). 

 

Stand alone printer as accessory.

 

PC connection as accessory, gate 

RS 485. No water connections 
required: Waste water can be 
plumbed into drain, but can also be 
collected in an optional waste 
container.

 

  
*NF HYGIENE ALIMENTAIRE certifying 
authority: AFAQ AFNOR CERTIFICATION. 
Adress:11, Avenue Francis de Pressense - 
93571 Saint-Denis La Plaine Cedex - France. 
Conformity with regulation NF031. Certified 
guarantees: fitness for cleaning, thermal 
performance

Summary of Contents for BCF7A 110781

Page 1: ...ling means bringing the temperature of cooked food from 90ºC to 3 C in a short time lap to minimize bacteria proliferation and avoid loss of food consistency and texture The ZANUSSI easyChill Blast Chillers Freezers reduce temperature to 3 C at food core in less than 90 minutes and down to 18 C in less than four hours After the Blast Chilling a holding cycle starts automatically to respectively ma...

Page 2: ...sting All parameters are programmable The control unit provides two large displays to read out time core temperature residual time alarms service information Two customizable cycles for each operating modes allowing setting time and air temperature These two programs P1 P2 can be converted into ice cream specialist cycles shape maintenance and holding All information related to the different opera...

Page 3: ...5 28 KG DCB01 2011 06 10 The Company reserves the right to alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L EI Electrical connection 230 V 1N 50 BCF7A 110781 LEGEND 110781 ...

Page 4: ...5 28 KG DCB01 2011 06 10 The Company reserves the right to alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L EI Electrical connection 230 V 1N 50 BCF15A 110721 LEGEND 110721 ...

Page 5: ...5 28 KG DCB01 2011 06 10 The Company reserves the right to alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L EI Electrical connection 400 V 3N 50 BCF28A 110722 LEGEND 110722 ...

Reviews: