7
Synthetic Paper Grease Filter
The filter has saturation indicators, which are small
squares made from a series of dots. When the white
paper inside the squares becomes saturated with grease
the coloured dots start to run and spread across the
paper, indicating that the filter has reached saturation
point and must be replaced.
The synthetic paper grease filter cannot be
cleaned.
It must not be washed.
To Replace the Synthetic Paper
Grease Filter
1.
Open the glass visor.
2.
Press inwardly on the two slide catches and the
grille will open from the front.
3.
Slide the right edge of the grille forward until it
clears the guide and then unhook the left hinge
pin.
4.
Carefully ease out the metal wire retaining clips.
5.
Clean the metal grille and clips before replacing
the filter.
Handle the wire clips with care and keep away
from children as they have sharp points.
This appliance can be a fire hazard if the
grease and charcoal filters are not cleaned and
replaced as recommended.
Changing the Light Bulb
If a lamp fails to function check that the bulb is screwed
into the holder.
If bulb failure has occurred then it should be replaced
with a 220-240V 40W clear cylindrical shape bulb with a
small E14 screw thread.