IMPORTANT SAFETY INFORMATION

These warnings are provided in the interests of your safety. Ensure that you understand them
all before installing or using this appliance. Your safety is of paramount importance. If you are
unsure about any of the meanings of these warnings contact the Customer Care Department.

Installation

• Any installation work must be undertaken by

a qualified electrician or a competent
person.

• This hood must be installed in accordance

with the installation instructions and all
measurements must be adhered to.

• If the cooker hood is installed for use above

a gas appliance then the provision for
ventilation must be in accordance with the
Gas Safety Codes of Practice BS.6172,
BS.5440 and BS.6891 (Natural Gas) and
BS.5482 (LP Gas) 1994, the Gas Safety
(Installation & Use) Regulations, the Building
Regulations issued by the Department of the
Environment, the Building standards
(Scotland) (Consolidated) Regulations
issued by the Scottish Development
Department.

• The fan motor of this cooker hood

incorporates a cut-out device which will
operate if the cooker hood is installed below
the minimum height recommended under
section ‘Clearance Height’, or if the motor
becomes overheated.  If the cut-out device is
activated, switch off the fan motor and allow
the cooker hood to cool.  The cut-out device
will reset  itself when the fan motor has
cooled significantly.

• It is dangerous to alter the specifications or

modify this product in any way.

• When installed between adjoining wall

cabinets the wall cabinets must not overhang
the hob.

• If the room where the hood is to be used

contains a fuel burning appliance such as a
central heating boiler then its flue must be of
the room sealed or balanced flue type.

• If other types of flue or appliances are fitted

ensure that there is an adequate supply of air
to the room.

• The ducting system for this appliance must

not be connected to any existing ventilation
system which is being used for any other
purpose.

• Do not install above a cooker with a high

level grill.

Child Safety

• This appliance is designed to be operated by

adults. Children should not be allowed to
tamper with the controls or play with the
appliance.

During Use

• This product is for domestic use only.

• Never leave frying pans unattended during

use as over-heated fats and oils might catch
fire.

• Never do flambé cooking under this cooker

hood.

• Do not leave naked flames under the hood.

Maintenance and Service

• This appliance can be a hazard if the

synthetic paper and charcoal filters are not
replaced as recommended.

• Under no circumstances should you attempt

to repair the appliance yourself. Repairs
carried out by inexperienced persons may
cause injury or more serious malfunction.
Refer to your local Zanussi Service Force
Centre.  Always insist on genuine spare
parts.

Summary of Contents for CH 6029 GR

Page 1: ...INTEGRATED COOKER HOOD CH 6029 GR INSTRUCTION BOOKLET ...

Page 2: ...nce For the User Important Safety Information Your Appliance Cooker Hood Controls To Operate Recirculation Extraction Maintenance and Cleaning External Cleaning Charcoal Filters To Remove the Charcoal Filters Synthetic Grease Filter To Remove the Grease Filter Changing the Light Bulb Something Not Working Service and Spare Parts Peace of Mind for Twenty Four Months Standard Guarantee Conditions Fo...

Page 3: ...he cut out device will reset itself when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or...

Page 4: ... hood a few minutes before you start cooking and leave it running for approximately 15 minutes after finishing Cooker Hood Controls The cooker hood functions are controlled by two slide switches located centrally in the front edge of the metal grille panel L Light ON OFF control V Fan Speed Control Position 0 Off Position 1 Low Position 2 Normal Position 3 Boost To Operate Select the required func...

Page 5: ...inated air is passed through the charcoal filter to be purified and recirculated into the kitchen through a recirculation grille Ensure the charcoal filters are in position When the ducting position is selected the charcoal filters are not required Never do flambé cooking under this cooker hood Never leave frying pans unattended during use as over heated fats and oils can catch fire Do not leave n...

Page 6: ...m your cooker hood replacement of the grease filter s will ensure good performance and reliability while extending the working life of the hood Charcoal Filter The charcoal filters absorb the odours from cooking They will slowly become saturated and gradually less effective The charcoal filters cannot be cleaned we recommend they are replaced every 3 6 months or more often if the hood is used for ...

Page 7: ...lace the Synthetic Grease Filter 1 Remove the lower grille 2 Push the wire retaining clips to the side and remove 3 Clean the metal grille and clips before replacing the paper grease filter The clips have sharp points handle with care and keep away from children This appliance is a possible fire hazard if the grease and charcoal filters are not replaced as recommended Changing the Light Bulb The b...

Page 8: ...he entry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been tripped Turn off the hob and then wait for the device to reset In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is n...

Page 9: ... parts of glass or plastic Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements Products of Zanussi manufacture which are not marked by Zanussi This guarantee is in addition to your statutory and legal rights ZANUSSI ...

Page 10: ...ion must comply with the latest I E E Regulations and local Electricity Board regulations For your own safety this should be undertaken by a qualified electrician e g your local Electricity Board or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC Electrical Connection Before connecting to the mains supply ensure that the mains volta...

Page 11: ...artition board structure then it should be sufficiently reinforced to be quite rigid in the area of the cabinet housing fixings Ducting The ducting must be fire retardant 125mm 5ins in diameter and the length should be no more than 3 metres with one 900 bend 2 metres with two 900 bends Bends of more than 900 will reduce the efficiency of the hood and reduce the airflow Clearance Height The cooker ...

Page 12: ...level grill Unpacking The fittings supplied to install this cooker hood can be found with the instruction book inside the packaging 120 125 mm ducting collar K Fitting the Cooker Hood into the Housing Canopy The hood is fixed to the housing using the screw holes located around the base of the casing Access to the screw holes will require the removal of the metal grille panel Positioning the Cooker...

Page 13: ...minimum The ducting used must be manufactured from fire retardant material When the hood is ducted externally the charcoal filters must be removed Recirculation If you are using the hood for recirculating ensure the charcoal filters are in position following the instructions below K Inserting the Charcoal Filters 1 Remove the grille panel support the grille with one hand and draw down on the two g...

Page 14: ...h 90 bend installed in the ducting run If the distance is greater than 3m the efficiency of the hood could be impaired A flange spigot of a 120 125 mm 5 is supplied for attaching to ducting if you are using the appliance in the extraction mode If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed ...