background image

7

Charcoal Filter

In  the  recirculation  mode  the  charcoal  filter  absorbs
smells and odours.

The charcoal filter cannot be cleaned, we recommend it
should be replaced approximately every three months
or  more  often  if  the  hood  is  used  for  more  than  three
hours per day.

To  Remove/Replace  the  Charcoal
Filter

1.

First remove the metal grease filters.

2.

Unscrew the two screws located on each side of
the charcoal filter.

This appliance can be a fire hazard if the
grease and charcoal filters are not replaced as
recommended.

To Change the Fluorescent Tube:

1.

Remove the plastic cover (T). The glass strip is
kept in position by retaining lugs (Z).

2.

Move the glass strip foward the control box until
the opposite end is free (arrow 1). Pull the glass
strip  slightly  down  (arrow  2)  and  then  move  it
back toward the opposite direction (arrow 3) until
the glass strip can be removed.

3.

The tube can removed by rotating it 90

°

.

4.

Replace with a new tube of the same type and
then  refit  the  plastic  cover  by  following
instructions 1 and 2 in reverse.

Summary of Contents for CWH 6065

Page 1: ...COOKER HOOD CWH 6065 9065X INSTRUCTION BOOKLET ...

Page 2: ...tion Your Appliance Recirculation Extraction Operating Instructions Cooker Hood Controls To Operate Maintenance and Cleaning External Cleaning Metal Grease Filters Remove the Metal Grease Filters Charcoal Filter To Remove Replace the Charcoal Filter Changing the Fluorescent Tube Something Not Working Service and Spare Parts Peace of Mind for Twenty Four Months Standard Guarantee Conditions For the...

Page 3: ...he cut out device will reset itself when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or...

Page 4: ...release To close control panel just push it back in This cooker hood is designed to extract unpleasant odours from the kitchen it will not extract steam The appliance can be installed to recirculate or extract contaminated air Recirculation The air is cleaned by passing through the filters and then back into the kitchen Extraction The contaminated air enters the hood passing through the grease fil...

Page 5: ...trol 0 Off 1 On C Fan Spedd control 1 Low 2 Normal 3 Boost When the red pilot light is on the cooker hood is in operation When used in the ducting mode the charcoal filter is not required Never do flambé cooking under this cooker hood Never leave frying pans unattended during use as over heated fats and oils might catch fire Do not leave naked flames under the cooker hood Ensure heating areas on y...

Page 6: ...rease filter absorbs grease and dust during cooking to help keep the appliance clean inside and should be cleaned approximately once every month or more often according to use Removing the metal Grease Filters 1 Remove the metal grease filters one at a time 2 Applying slight inward pressure to the metal bar situated in the slot this will release the securing bolts 3 Once the slot with the metal ba...

Page 7: ...ter This appliance can be a fire hazard if the grease and charcoal filters are not replaced as recommended To Change the Fluorescent Tube 1 Remove the plastic cover T The glass strip is kept in position by retaining lugs Z 2 Move the glass strip foward the control box until the opposite end is free arrow 1 Pull the glass strip slightly down arrow 2 and then move it back toward the opposite directi...

Page 8: ...sh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been tripped Turn off the hob and then wait for the device to reset In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical...

Page 9: ... parts of glass or plastic Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements Products of Zanussi manufacture which are not marked by Zanussi Ltd This guarantee is in addition to your statutory and legal rights ZANU...

Page 10: ...ments Any permanent electrical installation must comply with the latest I E E Regulations and local Electricity Board regulations For your own safety this should be undertaken by a qualified electrician e g your local Electricity Board or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC Electrical Connection Before connecting to the ...

Page 11: ...traction ducted to the outside or recirculation mode internal recycling The installation work must be undertaken by a qualified and competent person The manufacturer disclaims any responsibility for damages due to incorrect installation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling this type of installation The CWH 6065 9065 is Supplied with...

Page 12: ...en installed above a slot in electric cooker or 787mm 30 1 2 when installed above a slot in gas cooker When installed between adjoining wall cabinets the wall cabinets must not overhang the hob and the distance between the underside of the cabinet and the worktop must be 450mm If the height of the wall cabinet is less than 450mm a gap of 50mm must be maintained either side of the hob This cooker h...

Page 13: ...to the different height of this section needed to suit the ceiling height 7 Mark on the wall the centre of the two keyholes of the bracket 8 Pilot drill all the holes positions as marked on the wall using 8mm drill Fix the wall brackets 1 2 3 using the 8mm rawlplugs and screws supplied Fitting the Canopy 1 Rotate halfway the two screws R positioned on the hanging lugs of the canopy 2 Hook the cano...

Page 14: ...tlet on the top of the canopy using the two screws 2 Connect the ducting to the ducting spigot A using suitable clamps not supplied 3 The charcoal filter is not required when installed for extraction To remove see maintenance and cleaning section Recirculation The charcoal filter must be fitted for recirculation When the hood is installed in the recirculation mode the air is recirculated into the ...

Page 15: ...e fixed in a similar way between the wall brackets 1 and 3 and the wall paying attention to fit the lower part of the section into the recess of canopy 4 Then fix the lower section I to the wall bracket 1 using the two remaining self tapping screws Note The upper S and lower I sections are fixed to the wall bracket in the middle 3 through a spring and the connection is made by pushing both section...

Page 16: ...4323925 03 020625 Electrolux plc 2002 ...

Reviews: