5
E
N
G
L
IS
H
A4
TECHNICAL DATA
Standard cycle time may vary should the inlet water temperature be different from that indicated above.
(**) With dynamic feed pressure of 200 kPa [2 bar].
MODEL
ZUCA1
ZUCA3
NUC1 - EUC1
NUC1G - EUC1G
NUC3 - EUC3
Supply voltage:
V
220...240 1N~
400...415- 3N~
220...240 1N~
220...240- 1N~
400...415- 3N~
- convertible to
V
-
220...240- 3~
-
400...415- 3N~
220...240- 3~
- convertible to
V
-
220...240- 1N~
-
220...240- 3~
220...240- 1N~
Frequency
Hz
50 o 60
50 o 60
50 o 60
50 o 60
50 o 60
Max. power input
kW
3,65/5,65(*)
5,35/7,35(*)
3,65/5,65(*)
2,85/4,35(*)
5,35/7,35(*)
Boiler heating elements
kW
2,8
4,5
2,8
1,5
4,5
Tank heating elements
kW
2,0
2,0
2,0
2,0
2,0
Water supply press.
kPa [bar]
50...700 [0,5...7]
50...700 [0,5...7]
200...300 [2...3]
50...700 [0,5...7]
200...300 [2...3]
Water supply temp.
°C
50
50
50
50
50
Water supply hardness
°fH [°dH]
14 [8] max
14 [8] max
14 [8] max
14 [8] max
14 [8] max
Rinse cycle water
consumption
l
3
3
3,3 (**)
3,3
3,3 (**)
Boiler capacity
l
5,8
5,8
5,8
5,8
5,8
Tank capacity
l
33
33
33
33
33
Standard cycle time with
water supply at 50°C
sec.
90 - 120 - 240
90 - 120 - 240
120 - 180
120 - 180
120 - 180
Legal noise level Leq
dB(A)
<70
<70
<70
<70
<70
Protection rating
IPX4
IPX4
IPX4
IPX4
IPX4
Net weight
Kg
54
54
54
54
54
Power supply cable
H07RN-F
H07RN-F
H07RN-F
H07RN-F
H07RN-F
(*) = If activated by software, coincidence of tank and boiler heating elements.
Table 1
400..415 V 3N
220…240V 3
220…240V 1N
C
S
C
S
C
S
2,85 kW
5X1,5
16 A 3P+N
4X1,5
16 A 3P+N
3X2,5
16 A 1P+N
3,65 kW
-
-
-
-
3x2,5
20A 1P+N
4,35 kW
5X2,5
20 A 3P+N
4X2,5
20 A 3P+N
3X2,5
25 A 1P+N
5,35 kW
5X1,5
16A 3P+N
4X1,5
16A 3P+N
3x4
32A 1P+N
5,65 kW
-
-
-
-
3X4
32 A 1P+N
7,35 kW
5X2,5
25 A 3P+N
4X4
32 A 3P+N
3X6
40 A 1P+N
C = Power supply cable
S = On/Off switch
Table 2
Summary of Contents for EUC
Page 2: ......