17
TYPE
BURNER
INJECTORS
NORMAL
REDUCED
NORMAL
FEEDING
OF GAS
POWER
POWER
POWER
PRESSURE
1/100 mm
kW
kW
m bar
m
3
/h
g/h
Triple-crown
136
3,5
1,2
0,333
-
Semi-rapid
96
2,0
0,45
0,190
-
20
Auxiliary
70
1,0
0,33
0,095
-
Oven burner
116
3,0
1,0
0,286
-
Grill Burner
111
2,5
-
0,238
-
Triple-crown
93
3,5
1,2
-
252
Semi-rapid
71
2,0
0,45
-
144
Auxiliary
50
1,0
0,33
-
72
28-30/37
Oven burner
82
3,0
1,0
-
216
Grill burner
74
2,3
-
-
166
NATURAL
GAS
(Methane)
Technical data
LIQUID
GAS
(But./
Prop.)
Specifications for burners and injectors
Oven Heating elements rating
Bottom heating element
1,200 W
Top heating element
1,000 W
Electric Grill element
1,800 W
Oven Light
15 W
Turnspit
4 W
Convection Fan
30 W
Electric Plate
Ø 180mm - 1500 W
Voltage tension:
230 V ~ 50 Hz
Insertion possibility
In case of insertion of the appliance between kitchen
units, the dimensions to be respected are shown in fig.
28.
When the kitchen is installed according to class 2, sub-
class 1 (i.e. built-in) for the gas connection use only
flexible metallic tubes conforming to rules in force.
100
500
650
FO 1076
Fig. 28
Appliance Class 1 and Class 2, Sub-Class 1
Category:
II 2H3+
Appliance set for use with gas type: GPL 28-30/37 mbar