Replacing

Remove  the  grease  filters  and  take  out  the
activated charcoal filter from its housing, turning
the lugs provided 

(fig. 11)

. Insert the new activated

charcoal filter and replace the metal grease filters.

Enabling  the  alarm  signal

In  recirculation  type  hoods  the  saturated  filters
alarm must be enabled as indicated below:

- Turn off the lights 

T1

 and the suction motor 

T2

;

- Press  and  hold  the 

T4

  button  for  at  least  10

seconds, until the LEDs start to flash.  Note the
number of flashes:
-  2  flashes  of  the  LED   Activated  charcoal  filter
saturation alarm 

ENABLED

.

-  1  flash  of  the  LED    Activated  charcoal  filter
saturation alarm 

DISABLED

;

Resetting  the  alarm  signal

To turn the alarm signal off, proceed as follows:

- Press the 

T4

 button for at least 3 seconds, until the LEDs flash in confirmation.  In any

case the saturated filters alarm will only come into operation when the suction motor is
turned on.

WARNING: always comply with the maintenance and replacement times indicated,
in order to avoid a possible risk of fire when the filters are saturated with grease.

Lighting

• Version  with  halogen  spotlights:

90

  cm  model  two  20W  halogen

spotlights.

• To  replace  (fig.12)

Remove the two screws fixing the metal
ring, extract the spotlight from the lamp
holder by pulling gently. When replacing
the spotlight, make sure that the two pins
are correctly inserted in the housing on
the lamp holder.

Cleaning

When cleaning the hood:

- Never use a wet cloth or sponge, or running water.
- Never use thinners or products containing alcohol, as they might damage the paintwork.
- Never use abrasive cleaning materials, in particular when cleaning stainless steel surfaces.

It is recommended to use a damp cloth and mild liquid household cleaner.

Fig. 11

Fig. 12

Summary of Contents for NH 9015

Page 1: ...kap NH 9015 MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE HANDBOOK MANUEL D INSTRUCTIONS POUR L INSTALLATION L EMPLOI ET L ENTRETIEN HANDBUCH FÜR INSTALLATION BEDIENUNG UND WARTUNG INSTRUCTIES VOOR MONTAGE GEBRUIK EN ONDERHOUD ...

Page 2: ...i per l Uso 11 MANUTENZIONE 12 Filtri antigrasso metallici 12 Filtro al carbone attivo 12 Illuminazione 13 Pulizia 13 INSTALLATION 14 SAFETY WARNINGS 14 COMPONENTS 14 Installation instructions 15 Fitting the wall brackets and Splashback 15 Fixing the canopy 16 Electrical connection and working test 16 Ducting or Recirculation fitting 17 Fitting the telescopic chimney 18 OPERATION 19 Safety warning...

Page 3: ...g appliance Never do flambé cooking under this cooker hood Never leave frying pans unattended during use as overheated fats and oils may catch fire If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type If other types of flue or appliance are fitted en sure that there is an adequa...

Page 4: ...t the other bracket 2 against the wall aligning it with the vertical line at a distance X measured as shown in fig 2 equal to the height of the upper chimney element S supplied with the hood The position X may vary according to the various sizes of upper chimney element available d Mark the centres of the keyholes in the bracket on the wall Drilling fixing holes item 1 a Mark a point on the vertic...

Page 5: ...ktop and against the wall as illustrated in fig 2 b Mark the centres of the two holes in the top surface c Drill the wall using an 8 mm drill bit and fix the splashback using the rawl plugs and screws provided d If necessary the installer should secure the splashback to the wall by tucking the bottom edge down behind the rear of the worktop Fixing the canopy Before starting to fix the canopy it wi...

Page 6: ...e fitted to spigot R Make sure that the height of the assembly R P corresponds to the height of the chimney outlet fig 7 If the hood is supplied with the activated charcoal filters fitted the filters should be removed see paragraph on Maintenance Recirculation fitting The filtered air is returned to the room through the two plastic side grills G on the lower chimney element I Connect the additiona...

Page 7: ...t the lower section I as above between the upper section S and the canopy C using two of the screws provided in the bag of accessories Chimney with venting grilles Snap the venting grilles into position in the apertures located on the chimney section so that the symbol is turned upwards and the symbol faces forwards Also when the hood is used in recirculation mode ensure that the grilles are prope...

Page 8: ...ure that the flame is kept at the correct intensity to prevent the flame from licking round from the bottom of the pan this will save energy and will avoid a dangerous concentration of heat Always ensure that the appliance is used in accordance with the manufacturer s instructions for the removal of contaminated air and odours during cooking Instruction for Use Control panel The layout of the cont...

Page 9: ...etal grease filters so this function does not need to be enabled Resetting the alarm signal To turn the alarm signal off proceed as follows Turn off the lights T1 and the suction motor T2 Press the T4 button for at least 3 seconds until the LEDs flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on WARNING always comply with...

Page 10: ...the LEDs flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on WARNING always comply with the maintenance and replacement times indicated in order to avoid a possible risk of fire when the filters are saturated with grease Lighting Version with halogen spotlights 90 cm model two 20W halogen spotlights To replace fig 12 Remov...

Page 11: ... conforme à la norme européenne sur la basse tension C E E 73 23 relative à la sécurité électrique et aux normes européennes C E E 89 336 relative à la compatibilité électromagnétique et C E E 93 68 relative au marquage CE Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europäischen Richtlinien 89 336 EWG zur elektromagnetischen Verträg...

Reviews: