11
INSTALLING THE COOKER HOOD
Please ensure that when the appliance is installed it is
easily accessible to an engineer in the event of a
breakdown.
All installations must comply with the
local authorities requirements for the
discharge of exhaust air.
Incorrect installation may affect the
safety of this cooker hood.
Installation Requirements
Before installation check the wall to
which the cooker hood is to be fitted for
electric cables, water pipes or gas.
Ducting
The ducting must be fire retardant 125mm (5ins) in
diameter and the length should be nomore than:
3 metres with one 90
°
bend
2 metres with two 90
°
bends
Bends of more than 90
°
will reduce the efficiency of the
hood and reduce the airflow.
Clearance Height
The cooker hood is designed to be fitted over a cooking
appliance at the clearance heights stated, providing the
maximum output of the appliance beneath does not
exceed the maximums quoted in the Technical
Specifications.
If the output of the appliance below the cooker hood
exceeds the maximum outputs quoted, please refer to
the cooker manufacturer’s installation instructions.