75
Terminal block
The oven has an easily accessible terminal block,
which is meant to work with an electric single-phase
rate of 220-230 V.
(Fig. 18)
The manufacturer disclaims any
responsability should all the safety
measures not be carried out.
Fig. 18
Electric Connection
Before the appliance is connected:
1) check that the main fuse and the domestic installation
can support the load;
2) check that the power supply is properly earthed in
compliance with the current rules;
3) check the double pole switch used for the electrical
connection can be easily reached with the appliance
built in the forniture unit.
The appliance is supplied with a type H05 RR-F
connection cable, with section 3 x 1.5 mm
2
. A proper
socket, according to the electric load specified on the
rating plate, must be fitted to the cable.
In case of a direct connection to the mains, it is necessary
that you install a double pole switch between the
appliance and the electricity supply, with a minimum
gap of 3 mm. between the switch contacts and of a type
suitable for the required load in compliance with the
current rules.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature 50
°
C higher
than the room temperature.
After the connection is carried out, test the heating
elements for about 3 minutes.
FO 2159