Positioning
Install this appliance at a location where the
ambient temperature corresponds to the cli-
mate class indicated on the rating plate of the
appliance:
Climate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Electrical connection
Before plugging in, ensure that the voltage and
frequency shown on the rating plate corre-
spond to your domestic power supply.
The appliance must be earthed. The power
supply cable plug is provided with a contact for
this purpose. If the domestic power supply
socket is not earthed, connect the appliance to
a separate earth in compliance with current
regulations, consulting a qualified electrician.
The manufacturer declines all responsibility if
the above safety precautions are not observed.
This appliance complies with the E.E.C. Direc-
tives.
Door reversibility
The door of the appliance opens to the right. If
you want to open the door to the left, do these
steps before you install the appliance:
Loosen the upper pin
and remove the
spacer.
Remove the upper
pin and the upper
door.
Loosen the middle
hinge.
Remove the lower
door.
Loosen the lower pin.
On the opposite side:
Install the lower pin.
Install the lower door.
Install the upper door.
Tighten the spacer
and the upper pin.
Ventilation requirements
The airflow behind
the appliance must
be sufficient.
5 cm
min. 200cm
2
min.
200cm
2
Installing the appliance
Caution!
Make sure that the mains cable
can move freely.
Do the following steps:
23