17
FO 0939
FO 0938
Fig. 9
Fig. 10
Building In
On base cabinet with door
Adequate arrangements must be ensured in
the construction of the cabinet, to prevent possible
contact with the overheated housing of the top
during operation. The recommended solution for
avoiding this problem is illustrated in fig.8.
The panel under the top must be easily
removed to allow securing and release of the top
in case of technical service intervention.
On base cabinet with oven
The compartment must have the dimensions
given in fig. 5 and must be equipped with supports
for allowing efficient ventilation.
Two possible solutions for preventing
overheating are described in fig.9 and 10.
The electrical connection of the top and that of
the oven must be carried out separately, for
electrical reasons and to facilitate frontal oven
removal.
Wall units or extractor hoods must be at least
650 mm from the cooktop (Fig. 5).
Fig. 8
FO 1013
a) removable cabinet panel
b) possible space useful for connections