Problem
Possible cause
Solution
There is no voltage in the mains
socket (try to connect another ap-
pliance into it)
Call an electrician
The appliance does not
cool at all
Plug is not connected to the mains
socket properly
Connect the mains plug properly
There is no voltage in the mains
socket (try to connect another ap-
pliance into it)
Call an electrician
The appliance is not switched on
Switch on the appliance
Closing the door
1.
Clean the door gaskets.
2.
If necessary, adjust the door. Refer to "In-
stallation".
3.
If necessary, replace the defective door
gaskets. Contact the Service Center.
Installation
Caution!
Read the "Safety Information"
carefully for your safety and correct
operation of the appliance before installing the
appliance.
Positioning
This appliance should be installed in a dry, well
ventilated indoor where the ambient tempera-
ture corresponds to the climate class indicated
on the rating plate of the appliance:
Climate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Some functional problems might occur for some
types of models when operating outside of that
range. The correct operation can only be guar-
anteed within the specified temperature range. If
you have any doubts regarding where to install
the appliance, please turn to the vendor, to our
customer service or to the nearest Service Cen-
tre
Levelling
When placing the ap-
pliance ensure that it
stands level. This can
be achieved by two
adjustable feet at the
bottom in front .
Location
The appliance should be installed well away
from sources of heat such as radiators, boilers,
direct sunlight etc. Ensure that air can circulate
freely around the back of the cabinet. To ensure
best performance, if the appliance is positioned
below an overhanging wall unit, the minimum
distance between the top of the cabinet and the
wall unit must be at least 100 mm . Ideally, how-
ever, the appliance should not be positioned
below overhanging wall units. Accurate levelling
is ensured by one or more adjustable feet at the
base of the cabinet.
If the cabinet is placed in a corner and the side
with the hinges facing the wall, the distance be-
tween the wall and the cabinet must be at least
9