43
GB
Trouble shooting
During operation of the appliance some smaller but annoy-
ing trouble can often occur, which does not require calling
a technician out. In the following chart information is given
about them to avoid unnecessary charges on service.
We draw your attention that operation of appliance goes
with certain sounds (compressor- and circulating sound).
This is not trouble, but means normal operation.
Problem
The appliance does
not cool sufficiently
The appliance cools
too hard
The appliance does
not cool at all
The appliance is noisy
Possible cause
Thermostatic control is set too low.
Before freezing the appliance was not pre-
cooled sufficiently.
Large-sized food was put in.
Too many foods to be frozen were put in.
Warm foods were put in.
Door is not shut properly.
The thermostatic control is set too high.
Plug is not connected to the mains socket
properly.
There is no voltage in the mains socket.
Thermostatic control is in „STOP” position.
The appliance is not supported properly.
Solution
Set higher position.
Pre-cool the appliance for enough time.
Cut up food.
Put fewer foods to be cooled.
Put foods max. at room temperature.
Check if the door is shut.
Set lower position.
Check if the connection is proper.
Check if there is voltage.
Check setting of thermostatic control.
Check if the appliance stands stable.
Inasmuch as the advice does not lead to result, call the nearest brand-mark service.
Instructions for the Installer
Technical data
Model
Gross capacity (l)
Net capacity (l)
Width (mm)
Height (mm)
Depth (mm)
Energy consumption (kWh/24h)
(kWh/year)
Energy class, according to EU
Standards
Rated current (A)
Freezing capacity (kg/24h)
Rising time (h)
Weight (kg)
ZFX 305 W
50
50
525
520
587
0,48
175
A
0,7
7
17
25
We draw it to your attention again that the appliance
operates discontinuously, so the stopping of com-
pressor does not mean being no-current. That is why you
must not touch the electrical parts of the appliance before
breaking the circuit.