ADJUSTMENT OF MINIMUM LEVEL

To adjust the minimum level of the burners, proceed as
follows:

Light the burner.

Turn the knob on the minimum position.

Remove the knob.

With a thin screwdriver, adjust the by-pass screw
(see Fig. 10). If changing from natural gas to LPG,
completely tighten clockwise the screw, until a small
regular flame is obtained.

Finally check the flame does not go out when quickly
turning the knob from the maximum position to the
minimum position.

This procedure can easily be carried out, anyhow the
hob has been positioned or built in the working top.

  Burner

Ø By-pass

in 1/100

of mm.

  Auxiliary

28

  Semi-rapid

32

  Rapid

40

BY-pass diameters

Fig. 10

By-pass

screw

REPLACEMENT OF INJECTORS

• Remove the pan supports.

• Remove the burner's caps and crowns.

• With a socket spanner 7 unscrew and remove the

injectors (Fig. 9), and replace them with the ones
required for the type of gas in use (see table on the
next page).

• Reassemble the parts, following the same procedu-

re backwards.

• Replace the rating label (placed near the gas supply

pipe) with the relevant one for the new type of gas
supply. You can find this label in the package of the
injectors supplied with the appliance.

Should the feeding gas pressure be different or
variable compared with the required pressure, an
appropriate pressure adjuster (for non-LPG) must be
fitted on the gas supply pipe, in compliance with the
rules in force.

8. Adaptation to different types of gas

Fig. 9

FO 0392

TYPE

TYPE OF

INJECTORS

NOMINAL

REDUCED

NOMINAL

NOMINAL

OF GAS

BURNER

MARKS

POWER

POWER

POWER

PRESSURE

1/100 mm

INPUT

kW

mbar

KW

m3/h

g/h

Rapid (large)

119

3,0

0,65

0,286

-

Semi-rapid (medium)

96

2,0

0,45

0,190

-

20

Auxiliary (small)

70

1,0

0,33

0,095

-

Rapid (large)

86

2,8

0,65

-

202

Semi-rapid (medium)

71

2,0

0,45

-

144

28-30/37

Auxiliary (small)

50

1,0

0,33

-

72

NATURAL

GAS
G 20

LPG

Buthane
Propane

BURNERS

Summary of Contents for ZGF 646 ICW

Page 1: ...GAS HOBS ZGF 646 ICX ZGF 646 ICW OPERATING AND INSTALLATION MANUAL IT ...

Page 2: ...ying out any cleaning or manteinance work Ensure a good ventilation around the appliance A poor air supply could cause lack of oxygen Ensurethatthegassupplycomplieswiththegastype stated on the identification label placed near the gas supply pipe Using a gas cooking appliance will produce heat and moisture in the room which it has been installed in Ensure a continuous air supply keeping the air ven...

Page 3: ... out turn the knob to the symbol Always turn the flame down or put it out before taking the pans off the burner USING THE HOB CORRECTLY To ensure maximum burner efficiency it is strongly recommended that you use only pots and pans with a flat bottom fitting the size of the burner used so that flame will not spread beyond the bottom of the vessel see the table beside It is also advisable as soon as...

Page 4: ...crown holes lett B are not obstructed PAN SUPPORTS The hobs are provided with enamelled pan supports thin and light fig 2 To keep the pan supports in the right position they are hooked to a couple of special hinges in the back of the hob Thanks to these hooks you can lift the pan supports for easier cleaning as shown in fig 3 To take the pan supports completely off the hob proceed as shown in fig ...

Page 5: ...st care and attention For this reason we reccomend that for any problem you contact the dealer who sold it to you or our nearest authorized Service Centre specifying the nature of the problem and the particular model which you own 4 Mainteinance Technical Assistance FO 2237 ENAMELLED PAN SUPPORTS In hobs provided with enamelled pan supports these can be removed and kept in the right position thank...

Page 6: ...to carry out the work ensure all the necessary precautions are followed GAS CONNECTION Choose fixed connections or use a flexible pipe in stainless steel If using flexible metallic pipes be careful they do not come in contact with mobile parts or they are not squeezed Use the same attention when the hob is combinated with an oven IMPORTANT To ensure a correct operation a saving of energy and the l...

Page 7: ...oad in compliance with the current rules The earth cable yellow green must not be interrupted by the interrupter The connection cable has to be placed in order that in each part it cannot reach a temperature 90 C higher than the room temperature The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnected to the network phase REPLACEMENT OF THE VOLTAGE CABLE...

Page 8: ... Fig 9 and replace them with the ones required for the type of gas in use see table on the next page Reassemble the parts following the same procedu re backwards Replace the rating label placed near the gas supply pipe with the relevant one for the new type of gas supply You can find this label in the package of the injectors supplied with the appliance Should the feeding gas pressure be different...

Page 9: ...ve the right and left hand grid blocks fitted to the back of the hob by unscrewing the relevant screws fig 12 b Fit the lid hinge blocks onto the hob using the original screws ensuring that the relevant shims are fitted between the hinge blocks and the hob fig 16 c Fit the left hand lid hinge marked S into the hinge block fig 13 d Carry out the same operation with the right hand lid hinge marked D...

Page 10: ...Carry out the building in of the hob as follows put the relevant sealings supplied with the hob on the edges of the cut out as shown in Fig 16 taking care that the sealings meet without overlapping place the hob in the cut out taking care of its centring fix the hob with the relevant screws Fig 17 The traction of the screws is able to trace the sealing any excess of which can then be easily remove...

Page 11: ... hob recess dimensions must comply the indication given in Figs 19 and 22 and must be provided with brackets to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 20 e 21 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to allow the oven to be easily taken off the unit Hanging fornit...

Page 12: ...rld s largest producer of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world ...

Reviews: