8

Injectors replacement

• Remove the pan supports.

• Remove the burner's caps and crowns.

• With a socket spanner 7 unscrew and remove the

injectors (Fig. 8), and replace them with the ones
required for the type of gas in use (see 

Table 2

).

• Reassemble the parts, following the same procedure

backwards.

• Replace the rating label (placed near the gas supply

pipe) with the relevant one for the new type of gas
supply. You can find this label in the package of the
injectors supplied with the appliance.

Should the feeding gas pressure be different or variable
compared with the required pressure, an appropriate
pressure adjuster must be fitted on the gas supply pipe,
in compliance with the rules in force.

Fig. 8

FO 0392

Adjustment of minimum level

To adjust the minimum level of the burners, proceed as
follows:

• Light the burner.

• Turn the knob on the minimum position.

• Remove the knob.

• With a thin screwdriver, adjust the by-pass screw

(see Fig. 9). If changing from natural gas to LPG,
completely tighten clockwise the screw, until a small
regular flame is obtained.

• Finally check the flame does not go out when quickly

turning the knob from the maximum position to the
minimum position.

This procedure can easily be carried out, anyhow the
hob has been positioned or built in the working top.

  Burner

Ø By-pass

in 1/100

of mm.

  Auxiliary

28

  Semi-rapid

32

  Rapid

40

  Ultra rapid

56

Table 1 : BY-pass diameters

Table 2: Injectors

Fig. 9

By-pass screw

TYPE

TYPE OF

INJECTORS

NOMINAL

REDUCED

NOMINAL

NOMINAL

OF GAS

BURNER

MARKS

POWER

POWER

POWER

PRESSURE

1/100 mm

INPUT

kW

mbar

KW

m3/h

g/h

Ultra-rapid (large)

146

4,00

1,20

0,381

-

Rapid (large)

113

2,80

0,65

0,267

-

Semi-rapid (medium)

96

2,00

0,45

0,190

-

20

Auxiliary (small)

70

1,00

0,33

0,095

-

Ultra-rapid (large)

98

4,00

1,20

-

288

Rapid (large)

86

2,80

0,65

-

202

Semi-rapid (medium)

71

2,00

0,45

-

144

28-30/37

Auxiliary (small)

50

1,00

0,33

-

72

Ultra-rapid (large)

146

3,00

1,20

0,285

-

Rapid (large)

108

2,13

0,52

0,210

-

Semi-rapid (medium)

105

1,72

0,42

0,186

-

13*

Auxiliary (small)

80

0,90

0,30

0,085

-

NATURAL

GAS
G 20

LPG

(Buthane/

Propane)

Adaptation to different types of gas

NATURAL

GAS
G 20

* for Russia only.

Summary of Contents for ZGF 78 ICX

Page 1: ...GAS HOB ZGF 78 ICX INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance HR RO SLO CZ SK RU ...

Page 2: ...ould be retained with the appliance for future reference Should the appliance be sold or transferred always ensurethatthebookisleftwiththeapplianceinorder that the new owner can get to know the functions of the appliance and the relevant warnings This appliance has been designed for non professional purpose in private houses only It is meant to cook edible foodstuff only and MUST NOT be used for a...

Page 3: ...Using the hob correctly To ensure maximum burner efficiency it is strongly recommended that you use only pots and pans with a bottom fitting the size of the burner used so that flame will not spread beyond the bottom of the vessel see the table beside It is also advisable as soon as a liquid starts boiling to turn down the flame so that it will barely keep the liquid simmering Use only pans or pot...

Page 4: ...hem fall down To keep the pan supports in the correct position they are hooked into hinges at the back of the hob Thanks to these hooks you can lift the pan supports for easier cleaning When removing the pan supports lift them up as shown in Fig 2 Never turn the pan supports on the hinges this could damage them Fig 3 Keep the left pan support on the appropriate hook of the right pan support as sho...

Page 5: ...t the taps are periodically lubricated The periodic lubrication of the taps must be carried out by qualified personnel which you must refer to also in case of malfunctioning Technical Data This machine before leaving the factory has been tested and studied by many experts and specialists in order to give you the best results Any repair work which needs to be carried out should be done with the utm...

Page 6: ...le metallic pipes be careful they do not come in contact with mobile parts or they are not squeezed Use the same attention when the hob is combinated with an oven IMPORTANT To ensure a correct operation a saving of energy and the long life of the appliance the voltage pressure of the appliance must correspond to the recommended values Theadjustableconnectionisfixedtothecomprehensive ramp by means ...

Page 7: ...itch between the appliance and the electricity supply with a minimum gap of 3 mm between the switch contacts and ofatypesuitablefortherequiredloadincompliancewith the current rules The connection cable has to be placed in order that in each part it cannot reach a temperature 90 C The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnected to the network pha...

Page 8: ... gas to LPG completely tighten clockwise the screw until a small regular flame is obtained Finally check the flame does not go out when quickly turning the knob from the maximum position to the minimum position This procedure can easily be carried out anyhow the hob has been positioned or built in the working top Burner Ø By pass in 1 100 of mm Auxiliary 28 Semi rapid 32 Rapid 40 Ultra rapid 56 Ta...

Page 9: ...d the hob Fig 11 c Fit the left hand lid hinge marked S into the hinge block Fig 12 d Carry out the same operation with the right hand lid hinge marked D Adjusting the lid balance To adjust the lid balance turn clockwise or anti clockwise the central screw of the right and left hand hinges Fig 13 A Auxiliary burner SR Semi rapid burner R Rapid Burner UR Ultra rapid burner These hobs can be inserte...

Page 10: ... follows put the relevant sealings supplied with the hob on the edges of the cut out place them at 8 mm from the front and rear edge and at 50 mm from the side edges as shown in Fig 15 taking care that the sealings meet without overlapping place the hob in the cut out taking care of its centring fix the hob with the relevant screws Fig 16 The traction of the screws is able to trace the sealing any...

Page 11: ... to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 19 and 20 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to allow the oven to be easily taken off the unit Hanging forniture units or hoods must be placed at 650 mm minimum from the hob Fig 22 In case a hood with lenght of 600 ...

Reviews: