25
Engineers Technical Data
Gas burner power
Rapid burner (large)
2.9 kW (Natural gas 20 mbar)
2.7 (LPG 28-30/37 mbar)
Semirapid burner (medium)
1.9 kW
Auxiliary burner (small)
1.0 kW
Supply connections
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse.
Appliance class
3
Appliance category
II2H3+
Appliance gas supply
Natural gas G20 / 20mbar
Overall dimensions
Width
733 mm
Depth
513 mm
Cut out dimensions
Width
710 mm
Depth
470 mm
Instructions for the Installer
This appliance complies with the following EEC Directives:
-73/23
and
90/683
(on Low Voltage);
-89/336
(on Electromagnetic Compatibility);
-
90/396
(on Gas Appliances)
-93/68
(on General Standards) and subsequent amendments.