OTHER TECHNICAL DATA
TOTAL POWER:
Gas original:
G30/G31 (3B/P) 30/30 mbar
567 g/h
Gas replace-
ment:
G20 (2H) 20 mbar
8 kW
Electric supply:
220-240 V ~ 50-60 Hz
Appliance cate-
gory:
II2H3B/P
Gas connection:
G 1/2"
Appliance class:
3
GAS BURNERS FOR LPG G30/G31 30/30 mbar
BURNER
NORMAL POWER
kW
MINIMUM POW-
ER kW
INJECTOR MARK NOMINAL GAS FLOW
g/h
Rapid
2,8
0,75
86
204
Semi-rapid
2,0
0,45
71
145
Auxiliary
1,0
0,33
50
73
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW MINIMUM POWER kW
INJECTOR MARK
Rapid
3,0
0,75
119
Semi-rapid
2,0
0,45
96
Auxiliary
1,0
0,33
70
ENVIRONMENTAL CONCERNS
Recycle materials with the symbol . Put the
packaging in relevant containers to recycle it. Help
protect the environment and human health by
recycling waste of electrical and electronic
appliances. Do not dispose of appliances marked
with the symbol with the household waste.
Return the product to your local recycling facility or
contact your municipal office.
14