OTHER TECHNICAL DATA

TOTAL POW-

ER:

Gas original:

G20 (2H) 20 mbar

7,6 kW

Gas replace-

ment:

G30/G31 (3B/P) 30/30 mbar

545 g/h

G20 (2H) 13 mbar

8,0 kW (only for Russia)

Electric supply:

220-240 V ~ 50-60 Hz

Appliance cate-

gory:

II2H3B/P

Gas connec-

tion:

G 1/2"

Appliance

class:

3

GAS BURNERS FOR NATURAL GAS G20 20 mbar

BURNER

NORMAL POWER kW MINIMUM POWER kW

INJECTOR MARK

Rapid

2,9

0,75

119

Semi-rapid

1,85

0,45

92

Auxiliary

1,0

0,33

70

GAS BURNERS FOR LPG G30/G31 30/30 mbar

BURNER

NORMAL POWER

kW

MINIMUM POW-

ER kW

INJECTOR MARK NOMINAL GAS FLOW

g/h

Rapid

2,7

0,75

86

196

Semi-rapid

1,9

0,45

71

138

Auxiliary

1,0

0,33

50

73

GAS BURNERS FOR NATURAL GAS G20 13 mbar - RUSSIA ONLY

BURNER

NORMAL POWER kW MINIMUM POWER kW

INJECTOR MARK

Rapid

3,0

0,75

149

Semi-rapid

2,0

0,45

111

Auxiliary

1,0

0,33

82

ENERGY EFFICIENCY

PRODUCT INFORMATION ACCORDING TO EU 66/2014

Model identification

 

ZGO65414BA

14

Summary of Contents for ZGO65414BA

Page 1: ...GETTING STARTED EASY User Manual ZGO65414BA EN User Manual Hob KZ RU UA ...

Page 2: ...ion concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Keep all packaging away from children and dispose of it appropriately WARNING The appliance and its accessible parts become hot during use Keep children and pets away from the appliance when in use and when cooling down If the appliance has a...

Page 3: ...before installing it in the built in structure Do not use a steam cleaner to clean the appliance If the glass ceramic surface glass surface is cracked switch off the appliance and unplug it from the mains In case the appliance is connected to the mains directly using junction box remove the fuse to disconnect the appliance from power supply In either case contact the Authorised Service Centre In c...

Page 4: ... bottom of the appliance and the upper drawer is sufficient for air circulation The bottom of the appliance can get hot Install a non combustible separation panel under the appliance to prevent access to the bottom ELECTRICAL CONNECTION WARNING Risk of fire and electric shock All electrical connections should be made by a qualified electrician The appliance must be earthed Before carrying out any ...

Page 5: ...en is well ventilated especially when the appliance is in use Prolonged intensive use of the appliance may require additional ventilation for example the increasing of mechanical ventilation where present additional ventilation to safely remove the products of combustion to outside external air whilst also providing room air changes with additional ventilation Consult a qualified person before ins...

Page 6: ...tion of the surface material Switch off the appliance and let it cool down before cleaning Do not use water spray and steam to clean the appliance Clean the appliance with a moist soft cloth Use only neutral detergents Do not use abrasive products abrasive cleaning pads solvents or metal objects Do not clean the burners in the dishwasher SERVICE To repair the appliance contact the Authorised Servi...

Page 7: ...flame INJECTORS REPLACEMENT 1 Remove the pan supports 2 Remove the caps and crowns of the burner 3 With a socket spanner 7 remove the injectors and replace them with the ones which are necessary for the type of gas you use see table in Technical Data chapter 4 Assemble the parts follow the same procedure backwards 5 Replace the rating plate it is near the gas supply pipe with the one for the new t...

Page 8: ...on cable an adapter or a multiple connection Make sure that the ground connection agrees with the standards and regulations Do not let the power cable to heat up to a temperature higher than 90 C CONNECTION CABLE To replace the connection cable use only the special cable or its equivalent The cable type is H05V2V2 F T90 Make sure that the cable section is applicable to the voltage and the working ...

Page 9: ... assistance intervention is necessary Kitchen unit with door min 6 mm min 30 mm 60 mm min 5 mm max 150 mm A B A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit PRODUCT DESCRIPTION COOKING SURFACE LAYOUT 1 2 3 4 1 Rapid burner 2 Auxiliary burner ...

Page 10: ...me tries the burner does not light check if the crown and its cap are in correct positions WARNING Do not keep the control knob pushed for more than 15 seconds If the burner does not light after 15 seconds release the control knob turn it into off position and try to light the burner again after minimum 1 minute CAUTION In the absence of electricity you can ignite the burner without electrical dev...

Page 11: ...r Diameter of cook ware mm Rapid 180 240 Semi rapid 120 220 Auxiliary 80 180 CARE AND CLEANING WARNING Refer to Safety chapters GENERAL INFORMATION Clean the hob after each use Always use cookware with a clean base Scratches or dark stains on the surface have no effect on how the hob operates Use a special cleaner suitable for the surface of the hob WARNING Do not use knives scrapers or similar in...

Page 12: ...Refer to Safety chapters WHAT TO DO IF Problem Possible cause Remedy There is no spark when you try to activate the spark generator The hob is not connected to an electrical supply or it is con nected incorrectly Check if the hob is correctly connected to the electrical supply The fuse is blown Make sure that the fuse is the cause of the malfunction If the fuse is blown again and again contact a q...

Page 13: ...NO SER NO 03 IT MADE IN ITALY TYPE IP20 0049 A B C A Stick it on Guarantee Card and send this part if applicable B Stick it on Guarantee Card and keep this part if applicable C Stick it on instruction booklet TECHNICAL DATA HOB DIMENSIONS Width 590 mm Depth 520 mm BYPASS DIAMETERS BURNER Ø BYPASS 1 100 mm Rapid 42 Semi rapid 32 Auxiliary 28 13 ...

Page 14: ...kW INJECTOR MARK Rapid 2 9 0 75 119 Semi rapid 1 85 0 45 92 Auxiliary 1 0 0 33 70 GAS BURNERS FOR LPG G30 G31 30 30 mbar BURNER NORMAL POWER kW MINIMUM POW ER kW INJECTOR MARK NOMINAL GAS FLOW g h Rapid 2 7 0 75 86 196 Semi rapid 1 9 0 45 71 138 Auxiliary 1 0 0 33 50 73 GAS BURNERS FOR NATURAL GAS G20 13 mbar RUSSIA ONLY BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK Rapid 3 0 0 75 149 Semi...

Page 15: ...o the size of burners Center the pot on the burner When you heat up water use only the amount you need If it is possible always put the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer the liquid If it is possible use a pressure cooker Refer to its user manual ENVIRONMENTAL CONCERNS Recycle materials with the symbol Put the packaging in relevant containers t...

Page 16: ...WWW ZANUSSI COM SHOP 867305612 J 152022 ...

Reviews: