background image

36

Using the cooker hood

The hood is fitted with one motor having several
speed.

 

Best results are obtained by using a low

speed for normal conditions and high speed
when odours are more concentrated. Turn the
hood on a few minutes before you start cooking
then you will get an underpressure in the
kitchen. It should be left on after cooking for
about 15 minutes or until all odours have
disappeared.
The control switches are located on the unit’s
front panel:

Correct ventilation

If the cooker hood is to work correctly there must
be an underpressure in the kitchen. It is important
to keep the kitchen windows closed and have a
window in an adjacent room open.

Important to know

Not applicable for recirculation. Great care must be
taken if the hood is  used at the same time as a
burner or fireplace (e.g. gas, diesel, coal or  wood

Disconnect the cooker hood from the power supply prior to cleaning the appliance, either by removing the
plug from the mains or removing the fuse.

Clean the filter regularly.  The grease deposits in the filter and discharge tube are fire hazards where a
hotplate (or another heat source) is left on by error.

Maintenance and cleaning

Fig. 3

Cleaning the hood

Clean the outside of the hood using a damp cloth
and a mild detergent.
Never use corrosive, abrasive or flammable
cleaning products.

Cleaning the grease filters

Clean the filter every month or every other month
according to how much the hood is used.
The cleaner the filters, the more grease they
collect. To remove the filters, 

Fig. 3

:

First of all, push the stop on the metal grease
filter back, and then extract the filter by pulling
downward.

The filter is made of aluminium wires on which the
grease collects. Clean the filter in hot water using a
detergent, or in a dishwasher. Let the filter dry
before putting it back. Note that a dishwasher may
discolour the filter.

heaters, water heaters, etc.), as the hood will expel
air which is required by these other appliances.
Attend to it by opening a window. The negative
pressure in the room must not exceed 0,04 mbar to
prevent fumes being drawn back into the room by
the cooker hood.

Light switch

Motor switch

Summary of Contents for ZHC 632

Page 1: ...Instruktionsbok N DK S Käyttöohje FIN UK ZANUSSI Köksfläkt Ventilator Emhætte Liesituuletin CookerHood ZHC 932 ZHC 632 Bruksanvisning Brugsvejledning Operating and Installation Instructions ...

Page 2: ...ooker Note Cover the fire Never use water Never do any flambé cooking underneath the cooker hood It can cause a fire Remember that overheated fat may spontaneously ignite Never leave the frying pan unattended It is essential that the grease filter is regularly cleaned to help avoid fat dripping on to the hot zone and causing a fire Read the section on Maintenance and Cleaning in the instruction bo...

Page 3: ...ion spigot 1 plastic bag containing 2 wall hooks to fix the canopy hood 1 wall bracket to fix the chimney rawl plugs screws and documentation The following can be ordered from your retailer Charcoal filter PNC 942 120 892 The carbon filter is to be used when the hood is connected to the recirculation mode Extractor version The air is discharged to the outside through a pipe which must be fitted to...

Page 4: ...g the fuse Clean the filter regularly The grease deposits in the filter and discharge tube are fire hazards where a hotplate or another heat source is left on by error Maintenance and cleaning Fig 3 Cleaning the hood Clean the outside of the hood using a damp cloth and a mild detergent Never use corrosive abrasive or flammable cleaning products Cleaning the grease filters Clean the filter every mo...

Page 5: ...n the conveyor match with housing S on the charcoal filter then turn clockwise to fix it To remove proceed in the reverse order Always specify the hood model code number and serial number when ordering replacement filters This information is shown on the registration plate located on the inside of the unit The charcoal filter can be ordered from your local ELECTROLUX Service Force Centre Changing ...

Page 6: ...ic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the European Community EC or European Free Trade Area Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to anothe...

Page 7: ...her appliances that run on energy sources other than electricity Please keep to the provisions of official directives regarding fume discharge Electrical connection The hood has a power cable with earth connection and the rated voltage is 220 240V Assembling the chimney flue support bracket 3 parts The three parts should be fixed with 4 screws the support extension is adjustable and should corresp...

Page 8: ...les Y Mount the two rawl plugs with the hooks Hang the hood on the hooks and level it with the adjustment screws Remove the grease filters and mark for the 4 screws T R Remove the hood and drill the holes 4 x Ø 8 mm Insert the rawl plugs and fit two screws on upper holes do not tighten completely they will serve as additional hanging points Installation Fig 7 Fig 8 ...

Page 9: ...wall or roof exhaust channel Fitting for recirculation Mount the recirculation spigot with the 4 screws supplied Mounting the chimney Connect the supply cord to the mains Place the chimney and fix it to the top chimney holder with the two screws supplied Lower the bottom part of the chimney to the top of the hood Hooks Additional hanging points Centre line Chimney holder Lower screws Recirculation...

Page 10: ...42 ...

Page 11: ...43 ...

Page 12: ...LI15DA Ed 05 03 ...

Reviews: