12
Part 1 - INSTALLATION INSTRUCTIONS
1 - GENERAL DATA
This hood has been designed to be wall-mounted above a cooking hob with one side resting against a
wall. It works either by suction (external outlet) or filter (internal recycling).
Because of the complexity and weight of the hood, its installation should be carried out by qualified
staff, taking care to respect all local regulations on air discharge.
The manufacturer cannot be found liable for any damage due to improper installation.
2 - COMPONENTS
The cooker hood is made up of the following components (fig. 1):
2.1 - No. 1 canopy
C
complete with controls and worktop illumination;
2.2 - No. 1 telescopic chimney stack
A
complete with ducting fan unit;
2.3 - No. 1 flange Ø 120 or Ø 150
F
;
2.4 - No. 1 venting grill
G
;
2.5 - No. 1 ducting spigot
R
;
2.6 - No. 1 support rod
B
;
2.7 - No. 1 fixing kit containing:
No. 1 wall bracket
S
to fix the canopy hood;
No. 1 cover
D
, screws, rawl plugs and documentation.
3 - SAFETY WARNINGS
3.1 - When used in the extraction mode the cooker hood ducting must not be connected to
a flue which is used for exhausting fumes from appliances supplied with energy other
than electric such as a central heating flue or water heating flue.
3.2 - Before connecting to the mains supply ensure that the mains voltage corresponds with
the voltage on the rating plate inside the hood.
3.3 - Connect the cooker hood to the mains via a double pole switch which has 3 mm
1
A03_01
R
G
F
S
B
A
C