14
2 - Air discharge towards the wall
(fig. 3)
In this case the hood can only be used in suction mode.
3 - Side air discharge, Lh or Rh
(fig. 4a-b)
.
In this case the hood can only be used in suction mode.
4.2 - Installation of the hood canopy C
1 - Drilling the wall
a) Using the cardboard template provided, mark on the wall the centres of holes
1
for fixing of the
hood canopy
C
. The centre of hole
2
for fixing the chimney, (
fig. 5a
) air outlet directed upwards or
towards the wall, (
fig. 5b-c
) air outlet to the right or left hand side, must be marked at a distance
X
from the line between holes
1
, obtained by measuring the extension
Z
of the chimney required for
installation, plus 28 mm
X
=
Z
+35-7. Using a Ø8 mm drill bit, drill the points marked in this way.
b) When installed with the air outlet directed towards the wall (
fig. 5a
), it will be necessary to drill
an air ducting opening, measuring Ø120 or 150 mm, according to the diameter of the flange
F
provided.
ø120
ø150
100 100
ø 8
7
Z
X
76
35
650
105
105
A03_05
2
1
1
2
1
1
2
1
1
5a
5b
5c
S07_03
3
4a
4b
S07_04
R