background image

17

GB

• Replacing

Remove  the  grease  filters  and  take  out  the
activated charcoal filter from its housing, turning
the  lugs  provided 

(fig.  11)

.  Insert  the  new

activated  charcoal  filter  and  replace  the  metal
grease filters.

• Enabling the alarm signal

In  recirculation  type  hoods  the  saturated  filters
alarm must be enabled as indicated below:

- Turn off the lights and the suction motor;
- Press  and  hold  the 

T4

  button  for  at  least  10

seconds, until the LEDs start to flash.  Note the
number of flashes:
- 2 flashes of the LED  Activated charcoal filter
saturation alarm 

ENABLED

.

-  1  flash  of  the  LED    Activated  charcoal  filter
saturation alarm 

DISABLED

;

• Resetting the alarm signal

To turn the alarm signal off, proceed as follows:

- Press the 

T4

 button for at least 3 seconds, until the LEDs flash in confirmation.  In any

case the saturated filters alarm will only come into operation when the suction motor is
turned on.

WARNING: always comply with the maintenance and replacement times indicated,
in order to avoid a possible risk of fire when the filters are saturated with grease.

Lighting

• Version  with  halogen  spotlights:

90

  cm  model,  four  20W  halogen

spotlights.

• To  replace  (fig.12)

Remove  the  two  screws  fixing  the
metal ring, extract the spotlight from
the  lamp  holder  by  pulling  gently.
When  replacing  the  spotlight,  make
sure  that  the  two  pins  are  correctly
inserted  in  the  housing  on  the  lamp
holder.

Cleaning

When cleaning the hood:

• Never use a wet cloth or sponge, or running water.
• Never use thinners or products containing alcohol, as they might damage the paintwork.
• Never use abrasive cleaning materials, in particular when cleaning stainless steel surfaces.

It is recommended to use a damp cloth and mild liquid household cleaner.

Fig. 11

Fig. 12

Summary of Contents for ZHC 926 X

Page 1: ...ap ZHC 926 X MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE HANDBOOK MANUEL D INSTRUCTIONS POUR L INSTALLATION L EMPLOI ET L ENTRETIEN HANDBUCH FÜR INSTALLATION BEDIENUNG UND WARTUNG INSTRUCTIES VOOR MONTAGE GEBRUIK EN ONDERHOUD ...

Page 2: ... cm above a cooking appliance Never do flambé cooking under this cooker hood Never leave frying pans unattended during use as overheated fats and oils may catch fire If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type If other types of flue or appliance are fitted ensure that t...

Page 3: ...istance X measured as shown in fig 2 equal to the height of the upper chimney element S supplied with the hood The position X may vary according to the various sizes of upper chimney element available d Mark the centres of the keyholes in the bracket on the wall Drilling fixing holes item 1 a Mark a point on the vertical line at a distance from the cooking appliances of d 1045 min distance without...

Page 4: ... of the worktop Fixing the canopy Before starting to fix the canopy it will be necessary to adjust the support brackets S1 by turning the adjustment screws in a clockwise direction until their reach their limit Fig 3 a Hook the canopy onto the two size 4 2 x 44 4 screws 1 fitted as described above Fig 4 b Level the hood by turning the adjustment screws and then locking them Electrical connection a...

Page 5: ...et fig 6 Fit the activated charcoal filters inside the canopy see paragraph on Maintenance Do not fit the venting grilles until after the chimney has been installed Fitting the telescopic chimney To fit the upper section S first expand the two side pieces slightly hook them behind the brackets 2 and close them together again until they touch Fix the upper section S to the brackets 2 using four of ...

Page 6: ...flame is kept at the correct intensity to prevent the flame from licking round from the bottom of the pan this will save energy and will avoid a dangerous concentration of heat Always ensure that the appliance is used in accordance with the manufacturer s instructions for the removal of contaminated air and odours during cooking Instruction for Use Control Panel fig 9 The layout of the control pan...

Page 7: ...od is already set up to trigger an alarm indicating saturation of the metal grease filters so this function does not need to be enabled Resetting the alarm signal To turn the alarm signal off proceed as follows Turn off the lights and the suction motor Press the T4 button for at least 3 seconds until the LEDs flash in confirmation In any case the saturated filters alarm will only come into operati...

Page 8: ... LEDs flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on WARNING always comply with the maintenance and replacement times indicated in order to avoid a possible risk of fire when the filters are saturated with grease Lighting Version with halogen spotlights 90 cm model four 20W halogen spotlights To replace fig 12 Remove ...

Page 9: ... Cet équipement est conforme à la norme européenne sur la basse tension C E E 73 23 relative à la sécurité électrique et aux normes européennes C E E 89 336 relative à la compatibilité électromagnétique et C E E 93 68 relative au marquage CE Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europäischen Richtlinien 89 336 EWG zur elektrom...