17
GB
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
• Replacing
Remove the grease filters and take out the
activated charcoal filter from its housing, turning
the lugs provided
(fig. 11)
. Insert the new
activated charcoal filter and replace the metal
grease filters.
• Enabling the alarm signal
In recirculation type hoods the saturated filters
alarm must be enabled as indicated below:
- Turn off the lights and the suction motor;
- Press and hold the
T4
button for at least 10
seconds, until the LEDs start to flash. Note the
number of flashes:
- 2 flashes of the LED Activated charcoal filter
saturation alarm
ENABLED
.
- 1 flash of the LED Activated charcoal filter
saturation alarm
DISABLED
;
• Resetting the alarm signal
To turn the alarm signal off, proceed as follows:
- Press the
T4
button for at least 3 seconds, until the LEDs flash in confirmation. In any
case the saturated filters alarm will only come into operation when the suction motor is
turned on.
WARNING: always comply with the maintenance and replacement times indicated,
in order to avoid a possible risk of fire when the filters are saturated with grease.
Lighting
• Version with halogen spotlights:
90
cm model, four 20W halogen
spotlights.
• To replace (fig.12)
Remove the two screws fixing the
metal ring, extract the spotlight from
the lamp holder by pulling gently.
When replacing the spotlight, make
sure that the two pins are correctly
inserted in the housing on the lamp
holder.
Cleaning
When cleaning the hood:
• Never use a wet cloth or sponge, or running water.
• Never use thinners or products containing alcohol, as they might damage the paintwork.
• Never use abrasive cleaning materials, in particular when cleaning stainless steel surfaces.
It is recommended to use a damp cloth and mild liquid household cleaner.
Fig. 11
Fig. 12