40
This appliance complies with the following E.E.C.
Directives:
- 87/308 EEC of 2/6/87 relative to radio
interference suppression.
- 73/23 EEC of 19.2.73 (Low Voltage
Directive)
and subsequent modifications.
- 89/336 EEC of 3.5.89 (Electromagnetic
Compatibility Directive) and subsequent
modifications.
Attention!
It must be possible to disconnect the appliance
from the mains power supply; the plug must
therefore be easily accessible after installation.
Building-in
Dimensions of the recess
ZI 1603
ZI 2403
Height of housing (1) 880
1225
mm
Depth of housing (2)
550
550
mm
Width of housing (3)
560
560
mm
It is necessary that the niche is provided with a
conduct of ventilation having the following
dimensions:
Depth
50 mm
Width
540 mm
PR0
540
50
3
2
1
Electrical connection
Before plugging in, ensure that the voltage and
frequency shown on the serial number plate
correspond to your domestic power supply.
Voltage can vary by ±6% of the rated voltage.
For operation with different voltages, a suitably sized
auto-transformer must be used.
Important
The appliance must be earthed.
The power supply cable plug is provided with a
contact for this purpose.
If the domestic power supply socket is not
earthed. connect the appliance to a separate
earth in compliance with current regulations,
consulting a specialist technician.
The Manufacturer declines all
responsibility if the above safety
precautions are not observed.
D132
2. Apply joint the sealing strip as shown in figure.
D022
1
2
1.
Slide the appliance into the recess, pushing it
against the wall on the handle side.
Summary of Contents for ZI 2403