Minimum space above hob level
787mm (If a cooker hood is fitted refer to the cooker-
hood installation instructions)
Connections
Gas connection
Rear left hand side of appliance at hob level. Rc ½" ( ½
" B.S.P. female)
Electrical connection
None
Ignition
Battery 1.5 Volt AA size
GAS CONSUMPTION TABLE
LPG
GB: I3+
IE: I3+
NG
GB: I2H
LARGE BURNER
INJECTOR
85
115
NOMINAL RATING (KW)
3
3
CONSUMPTION IN 1h
218.3 gr/h
285.7 lt/h
MEDIUM BURNER
INJECTOR
65
97
NOMINAL RATING (KW)
1.75
1.75
CONSUMPTION IN 1h
127.25 gr/h
166.7 lt/h
SMALL BURNER
INJECTOR
50
72
NOMINAL RATING (KW)
1
1
CONSUMPTION IN 1h
72.7 gr/h
95.3 lt/h
MAIN OVEN BURNER
INJECTOR
98
115
NOMINAL RATING (KW)
2.4
2.4
CONSUMPTION IN 1h
174.5 gr/h
228.6 lt/h
TOP OVEN BURNER
INJECTOR
98
115
NOMINAL RATING (KW)
2.4
2.4
CONSUMPTION IN 1h
174.5 gr/h
228.6 lt/h
GRILL BURNER
INJECTOR
68
110
27