Special conditions
If the floor is carpeted or covered with crumbly
or soft material, insert a rigid support base
under the feet to prevent noise, vibration or
displacement. The base should protrude a few
centimetres beyond the edges of the machine.
WARNING!
The machine should NOT be placed on deep
pile carpeting.
NOTE
Please ensure that when the appliance is
installed it is easily accessible for the engineer
in the event of a breakdown.
In the interest of the environment
Washer-dryers should be connected to the
FOUL drainage system, the water will then be
taken to a sewage works for treatment before
being discharged safely into a river. It is
essential that these appliances are not
connected to the surface water drainage
system as this water is discharged directly into
a river or stream and may cause pollution.
If you require any further advice please
contact your local water authority.
SHOWER
BATH
SINK TOILET
BIDET
WASHING
MACHINE
DISHWASHER
RAINWATER
'RUN-OFF'
SURFACE WATER
DRAINS & SEWERS
UNTREATED
DISCHARGE
RIVER
FOUL DRAIN
FOUL SEWERS
SEWAGE
TREATMENT
WORKS
RIVER
TREATED
DISCHARGE
Electrical connection
Any electrical work required to install this
appliance should be carried out by a qualified
electrician or competent person.
WARNING!
This appliance must be earthed.
The manufacturer declines any liability
should this safety measure not be
observed
.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the appliance’s rating plate.
IMPORTANT!
Information on the electrical connection is
given on the rating plate on the inner edge
of the appliance door.
The appliance is supplied with a 13amp plug
fitted. In the event of having to change the fuse
in the plug supplied, a 13amp ASTA approved
(BS1363/A) fuse must be used.
Should the plug need to be replaced for any
reason, proceed as described below.
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow ..............................- Earth
Blue ....................................................- Neutral
Brown..................................................- Live
The wire coloured green
and yellow must be
connected to the
terminal marked with
the letter «E» or by the
earth symbol
or
coloured green and
yellow.
The wire coloured blue must be connected to
the terminal marked «N» or coloured black.
The wire coloured brown must be connected to
the terminal marked «L» or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp
must be secure over the outer sheath.
GREEN & YELLOW
BROWN
CORD CLAMP
BLUE
13
A
E
N