20

When building in ceramic glass cooking areas the front

cross-rail of the build-in cupboard must be removed in

order to have the heat radiating off escape without any

obstacles.

The space under the hob unit must be closed at all

sides in a way that the lower side of the cooking area

is no longer accessible.

The distance from the hob to the furniture part under

the hob must at least amount to 20 mm. If needed,

please fix an insulation. Drawers must not be located

under a hotplate.

The distance from the hob to a high cupboard beside

right or left must at least amount 55 mm, to the back

wall at least amount 55 mm.

With regard to the protection against overheating of

surrounding furniture surfaces this appliance corres-

ponds to type Y (EN 60335). This appliance or the

built--in cupboard for the appliance respectively may be

located with the rear wall and one side wall to whatever

high walls or furniture respectively and with the other

side to another appliance or furniture of the same

height as this appliance.

Built-in dimensions

The opening in the worktop must correspond to com-

mercial dimensions. The hints required are given in the

dimension sketch.

Built-in

Cut out the worktop acc. to prescribed cutout size. The

tolerance sizes must not be exceeded. Do precisely

saw at the mark line. Recommendation: Mark the cut-

out with a steel needle. Glue something on the line in

order to avoid shattering of the coat when cutting.

With tile--coated worktop areas the slits in the support-

ing area for the cooking area must be filled up com-

pletely.

Clean the worktop in the cutout area

From the top lay the cooking area into the cutout, adjust

concentrically and firmly press down.

Check the sealing in the supporting frame for perfect

seating and resting without a gap. Please do not apply

additional silicone sealing material, the closure will

make it harder to dismantle in case of need for service.

5 holes in the bottom of the build--in case are provided

for the screws of the fitting plates.

At first screw on the fitting plates by a screwdriver and

afterwards regularly tighten the plates alternatively and

diagonally offset, until the frame of the cooking area is

perfectly laying on the worktop.

A too strong and one--sided tightening is to be avoided!

Electric screwdrivers or pusher airscrews to be exclu-

sively used with slip clutch (setting value 1 -- 1.1 Nm).

Worktop opening:

width: 560 mm

depth: 490 mm

radius:

5 mm

Appliance:

width: 572 mm

depth: 502 mm

heigth : 49 mm

Voltage:

AC 230 V 50 Hz/60 Hz

Total connected load:

5,8 kW

1

2

572

502

heigth of the hob

49 mm

heigth of frame

over worktop

3 mm

Frame measurement

on worktop 9 mm

R5

hobs frame

ceramic glass plate

fixing clamp

Points for fixing clamps

Measurement of

490

+

1

560

+

1

worktop

49 mm

Summary of Contents for ZKL 64 B

Page 1: ...Operating and Installation Instruction Electric Ceramic glass Hob ZKL 64 W ZKL 64 B ZKL 64 N ZKL 64 X GB 319 3900 00 K RD SD 980223 ...

Page 2: ...e and operation In case of careless handling there is danger of bur ning oneself at the heating elements in the cooking area Do not switch on cooking zones unless pots or pans are placed on them Vessels and their bottoms have to be dry and clean Do not use hobs for parking any objects The preparation of food in aluminum foil or plastic con tainers is not allowed The hob gets damaged when you opera...

Page 3: ...s transport damages must not be con nected to the mains First cleaning In order to remove possible production remnants clean the appliance once prior to the first use Remove any possibly existing labels and protective foils from the ceramic glass surface Clean the ceramic glass plate and the frame with hot water and a washing up liquid and wipe it dry First heating up The cooking zones are to be s...

Page 4: ...ated by means of 4 energie controlled switches on the right of the hob You may set the desired output by setting to positions 1 9 The setting knobs have to be turned to the rigth to the desired output Position 9 refers to the highest and 1 to lowest output 0 is the OFF position The setting chart provides you with hints for practical use Switch off Switch off your cooking zones by turning the knobs...

Page 5: ...ding cleaning of vegetable get on the cooking surface when the pot is moved around on it Dishes with aluminium and copper bottoms may leave metallic discolouration on the ceramic glass surface which is only hard to remove or even not at all Intelligent consumption of energy To save energy you should D exclusively make use of suitable boiling and roasting vessels with smooth and even bottom D on pr...

Page 6: ...to the hot ceramic glass surface Cleansing agents have always to be wiped off comple tely with a damp cloth as they have an corrosive effect when reheated Finally wipe dry Never use any aggressive or scouring clean sing agents such as grill or oven sprays stain or rust removers scouring powder or scouring sponges Special problems when a chemical cleansing agent is not suffi cient The razor blade s...

Page 7: ...rderly Do please adhere to the national and regional prescrip tions material separation waste collection residuary product yards Installation in the kitchen worktop Electrical safety is to be ensured by professio nal installation Protection against accidental contact accor ding to the regulations set by VDE or other local authorities and EN 60335 must be ensured by correct installation of the appl...

Page 8: ...cisely saw at the mark line Recommendation Mark the cut out with a steel needle Glue something on the line in order to avoid shattering of the coat when cutting With tile coated worktop areas the slits in the support ing area for the cooking area must be filled up com pletely Clean the worktop in the cutout area From the top lay the cooking area into the cutout adjust concentrically and firmly pre...

Page 9: ...rew driver pict According to existing mains voltage the appliance has to be connected in correspondence with the diagrams of connecting possibilities The bridges of the terminal board are to be changed accordingly if need be The protective conductor is to be connected to terminal The protective conductor must be longer than live leads The cable connections have to be established as prescribed and ...

Page 10: ...ax Address Tel Fax The type plate is placed on the bottom of the appliance After built in and installation you cannot look at this informations So please notice the F Nr into the beside type plate Type plate This appliance is corresponding to the EG rules 73 23 EWG 89 336 EWG 90 683 EWG MADE IN GERMANY TYP PEE2 011 PNC 949 590 585 MODELL ZKL 64 W AC 230 V Total max 5 8 kW F Nr MADE IN GERMANY TYP ...

Page 11: ...319 3900 00 K RD SD 980928 ...