4
SLX-2 Functional Diagram
Notes:
•
24dB mode is only valid on X2’s output - lowpass mode only.
X2’s output in this mode is automatically mono.
•
Frequency range switch only effects X1’s outputs - but can
effect X2’s output when output switch is set to “X1-HI”.
•
When X2 output is set to “X1-HI”, the X1 FREQ control
effects both outputs. The X2 FREQ control is deactivated in
this mode.
•
X2 input in not functional when the “Input Mode” switch is in
the “2CH” position. X2 input only activated by engaging the
“4CH” mode.
•
Either output can be selected as highpass or lowpass. They
can be set the same or opposite of each other.
•
One output can be fed into the opposite input. When doing
this, you must engage the 4CH input mode. This feature
allows the capability of “1-way” 24 dB or bandpass
configurations.