12
Troubleshooting
Symptom
Possible cause / cure
The muting effect is
audible.
1.
Set the range switch to lowpass.
2.
Reduce the threshold level.
3.
Lengthen the decay time.
The power LED does
not come on.
1.
Connect the mute to the source
unit’s remote turn-on lead.
2.
Check the power and grouind
connections.
The unit never seems
to gate, the gate LED is
always off.
Check the ENABLE switch setting.
The unit never seems
to un-gate, the gate
LED is always on.
Make sure that you are using the front
channel inputs in a two channel
system.