AE0ZP0EC - AC-0 SSL SENSORED - User Manual
Page - 27/100
A20
ENC B
Encoder Channel B.
CNB connector
B1
KEY SW
Connected to the power supply through a microswitch
(KEY) with a 6.3-10 A fuse in series (this can be
mounted on the AC-0 cover).
B2
CM
Common of SEAT / LIFT ENABLE / HYDRO
STEERING / SR / SPEED 1 / SPEED 2 /SPEED 3 /
SPEED 4 microswitches. This connection supplies a
key voltage level.
B3
SEAT SWITCH
Seat presence signal; it is active high.
B4
FREE
It is a free input.
B5
SPEED 1
Input for first speed request; it is active high.
B6
LIFT ENABLE
Input for potentiometer lifting enable input; it is active
high.
B7
HYDRO STEER Input for hydraulic steering request. Active high.
B8
SR
Speed reduction input. Active low (switch opened).
B9
SPEED 4
Input for fourth speed request; it is active high.
B10
CPOT
Lift potentiometer wiper.
B11
NPOT
Negative of accelerator unit, tested for wire
disconnection diagnosis.
B12
PPOT
Potentiometer positive: 10 V output; keep load > 1 k
Ω
.
CNC connector
C1
PCLRXD
Positive serial reception.
C2
NCLRXD
Negative serial reception.
C3
PCLTXD
Positive serial transmission.
C4
NCLTXD
Negative serial transmission.
C5
GND
Negative console power supply.
C6
+12V
Positive console power supply.
C7
FLASH
Must be connected to C8 for the Flash memory
programming (if used).
C8
FLASH
Must be connected to C7 for the Flash memory
programming (if used).