AE0ZP0EC - AC-0 SSL SENSORED - User Manual
Page - 41/100
9.4 Function configuration
9.4.1 Traction
We will describe two configurations depending on the MDI-PRC setting (see “Set
options” submenu):
1) STANDARD version (MDI-PRC Absent)
2) MDI-PRC version (MDI-PRC Present). In this case the drive control
communicates with a MDI-PRC through the CAN BUS.
They have different list of settings (the Standard version has a reduced settings
list). In the next we refer to a complete settings that is the sum of the settings list
of both the above configurations. When the setting refers to only one
configuration, it will be specified in the description.
Using the CONFIG MENU of the programming console, the user can configure
the following functions (see "OPERATIONAL FEATURE" chapter for an
explanation of "hydraulic steering function"):
"SET OPTIONS" SUBMENU
1) TILLER
SWITCH
This option handles the input CNB#3. This input opens when the operator
leaves the truck (released). It is connected to a key voltage when the
operator is present. There are two levels:
- HANDLE:
CNB#3 is managed as tiller input (no delay when
released).
- SEAT:
CNB#3 is managed as seat input (with a delay when
released).
2) SET
INPUT
#1
This setting handles the analog input CNA#13. It can be used one of three:
-
Level 0:
CNA#13 is managed as input for an analog motor thermal
sensor KTY84-130.
-
Level 1:
CNA#13 is managed as a digital cutback speed input
(SR#1).
-
Level 2:
CNA#13 is managed as a digital handbrake input.
When Level 1 or 2, this input must be connected to a -Batt voltage in order
the selected function is not active; it must be opened to turn the selected
function active.
3) SET
INPUT
#2
(Standard Version only). This option handles the digital input CNA#14. It can
be used one of two:
-
PRESENT:
CNA#14 is managed as a cutback speed input (SR#2)
-
OPTION #1: CNA#14 is managed as an inching forward input
The input CNA#14 can only be used as Aux Lifting request when the MDI-
PRC is PRESENT.
This input must be connected to a Key voltage.
The SR#2 becomes active when CNA#14 is opened.
The inching forward becomes active when the CNA#14 is closed to a key
voltage.