Page - 46/100
AE0ZP0EC - AC-0 SSL SENSORED - User Manual
"ADJUSTMENTS" SUBMENU
1) SET POT BRK MIN
(Standard version only). This setting records the minimum value of braking
pedal potentiometer when the braking pedal switch is closed; the procedure
is similar to the PROGRAM VACC function (see paragraph 10.3). This
procedure must be carried out only if the PEDAL BRAKING option is
programmed as ANALOG.
2) SET POT BRK MAX
(Standard version only). This setting records the maximum value of braking
pedal potentiometer when the braking pedal is fully pressed; the procedure is
similar to the PROGRAM VACC function (see paragraph 10.3). This
procedure must be carried out only if the PEDAL BRAKING option is
programmed as ANALOG.
3) MIN
LIFT
(MDI-PRC version only). By entering this setting, the SW records the actual
value of the CNA#18 potentiometer. The MIN LIFT setting must be Entered
with the potentiometer in a position is a little bit ahead the main Lifting switch
(CNB#9) turns closed.
4) MAX
LIFT
(MDI-PRC version only). By entering this setting, the SW records the actual
value of the CNA#18 potentiometer. The MAX LIFT setting must be Entered
after the Lifting control Lever is pushed against the maximum limiting
position.
5) MIN
LOWER
(MDI-PRC version only). By entering this setting, the SW records the actual
value of the potentiometer on CNA#18. The MIN LOWER setting must be
Entered with the CNA#18 potentiometer in a position is a little bit ahead the
Main Lowering switch (CNB#8) turns closed.
6) MAX
LOWER
(MDI-PRC version only). By entering this setting, the SW records the actual
value of the potentiometer on CNA#18. The MAX LOWER setting must be
Entered after the Lowering control Lever moving the CNA#18 potentiometer
is pushed against the maximum limiting position.
7) MOTOR
OVERTEMP
With this setting, it is possible to raise a warning when the motor temperature
overtakes a threshold specified by the MOTOR OVERTEMP value.
8) SET MOT TEMP.
With this setting, it is possible to get a fine adjustment of the temperature of
the motor measured by the controller.
9) SET BATTERY TYPE
It selects the nominal battery voltage.
10) ADJUST BATTERY
Fine adjustment of the battery voltage measured by the controller.
11) THROTTLE 0 ZONE
It establishes a deadband in the accelerator input curve (see also paragraph