6) ADJ MOT TEMP
With this setting, it is possible to get a fine adjustment of the temperature of
the motor measured by the controller.
7) SET BATTERY TYPE
It selects the nominal battery voltage.
8) ADJUST
BATTERY
Fine adjustment of the battery voltage measured by the controller.
9) THROTTLE 0 ZONE
It establishes a deadband in the accelerator input curve (see also paragraph
10.5).
10) THROTTLE X POINT
This parameter, together with the THROTTLE Y POINT, changes the
characteristic of the accelerator input curve (see also paragraph 10.5): when
the accelerator is depressed to X point per cent, the corresponding truck
speed is Y point per cent of the Maximum truck speed. The relationship
between the accelerator position and the truck speed is linear between the
THROTTLE 0 ZONE and the X point and also between the X point and the
maximum accelerator position but with two different slope (see also Figure
10–2).
11) THROTTLE Y POINT
This parameter, together with the THROTTLE X POINT, changes the
characteristic of the accelerator input curve (see also paragraph 10.5): when
the accelerator is depressed to X point per cent, the corresponding truck
speed is Y point per cent of the Maximum truck speed. The relationship
between the accelerator position and the truck speed is linear between the
THROTTLE 0 ZONE and the X point and also between the X point and the
maximum accelerator position but with two different slope (see also Figure
10–2).
12) ADJUSTMENT #01
It adjusts the upper level of the battery charge table (Level 0 to 9). See
paragraph 10.6.
13) ADJUSTMENT #02
It adjusts the lower level of the battery charge table (Level 0 to 9). See
paragraph 10.6.
14) LOAD HM FROM MDI
When set On, the HourMeter of the Controller is transferred and recorded on
the HourMeter of the Standard MDI (connected on the Serial Link).
15) CHECK UP DONE
Turn it On when the asked Maintenance service has been executed to cancel
the CHECK UP NEEDED warning.
16) CHECK UP TYPE
It specifies the handling of the CHECK UP NEEDED warning:
-
NONE:
No CHECK UP NEEDED warning.
-
OPTION #1: CHECK UP NEEDED warning on the hand set after 300