AE0ZP0EC - AC-0 SSL SENSORED - User Manual
Page - 65/100
11) ACCELERATOR
From 0.0 V to 5.0 V. The voltage on the wiper of the accelerator (CPOT on
CNB#10) is halved inside the controller and then recorded on this reading.
That means the actual wiper voltage is in the range 0 to 10 V meanwhile the
corresponding ACCELERATOR reading is in the range 0.0 to 5.0 Vdc.
12) BRAKEPEDAL POT.
(Standard Version only). From 0.0 V to 5.0 V. When the MDI-PRC is absent,
the potentiometer connected to CPOTB on CNA#18 is used for a brake pedal
sensor. The voltage on the wiper of this brake pedal potentiometer (CNA#18)
is halved inside the controller and then recorded on this reading. That means
the actual wiper voltage is in the range 0 to 10 V meanwhile the
corresponding BRAKE PEDAL POT reading is in the range 0.0 to 5.0 Vdc.
13) LIFTING CONTROL
(MDI-PRC Version only). From 0.0 V to 5.0 V. When the MDI-PRC is present,
the potentiometer connected to CPOTB on CNA#18 is used for a proportional
control of the hydraulics. The voltage on the wiper of this potentiometer
(CNA#18) is halved inside the controller and then recorded on this reading.
That means the actual wiper voltage is in the range 0 to 10 V meanwhile the
corresponding LIFTING CONTROL reading is in the range 0.0 to 5.0 Vdc.
14) LIFTING SWITCH
ON/OFF. This is the level of the CNB#9 digital input (Lifting request):
-
ON +VB =
When CNB#9 is closed to a battery (key) voltage, the
Lifting request is Active.
-
OFF GND=
When CNB#9 is not connected to a battery (key) voltage
(or it is connected to GND), the Lifting request is not
active.
15) DESCENT SWITCH
ON/OFF. This is the level of the CNB#8 digital input (Lowering request):
-
ON +VB =
When CNB#8 is closed to a battery (key) voltage, the
Lowering request is Active.
-
OFF GND=
When CNB#8 is not connected to a battery (key) voltage
(or it is connected to GND), the Lowering request is not
active.
16) DIGITAL INPUT #1
(MDI-PRC version only). ON/OFF. This is the level of the CNA#14 digital
input (when the MDI-PRC is present this input is an Auxiliary (2
nd
) Lifting
request):
-
ON +VB =
When CNA#14 is closed to a battery (key) voltage the
Aux Lifting request is active.
-
OFF GND =
When CNA#14 is not closed to a battery (key) voltage (or
it is connected to GND) the Aux Lifting request is not
active.
17) DIGITAL INPUT #2
(MDI-PRC version only). ON/OFF. This is the level of the CNA#15 digital
input (when the MDI-PRC is present this input is an Auxiliary (2
nd
) Lowering
request):
-
ON +VB =
When CNA#15 is closed to a battery (key) voltage the
Aux Lowering request is active.
-
OFF GND =
When CNA#15 is not closed to a battery (key) voltage (or