Page - 66/100
AE0ZP0EC - AC-0 SSL SENSORED - User Manual
it is connected to GND) the Aux Lowering request is not
active.
18) FORWARD SWITCH
ON/OFF. This is the level of the CNB#6 digital input (Forward Travel
demand):
-
ON +VB =
When CNB#6 is closed to a battery (key) voltage, the
Forward Travel demand is Active.
-
OFF GND=
When CNB#6 is not connected to a battery (key) voltage
(or it is connected to GND), the Forward Travel demand is
not active.
19) BACKWARD SWITCH
ON/OFF. This is the level of the CNB#5 digital input (Backward Travel
demand):
-
ON +VB =
When CNB#5 is closed to a battery (key) voltage, the
Backward Travel demand is Active.
-
OFF GND=
When CNB#5 is not connected to a battery (key) voltage
(or it is connected to GND), the Backward Travel demand
is not active.
20) HANDLE/SEAT SW.
ON/OFF. This is the level of the CNB#3 digital input (Tiller or seat swit.):
-
ON +VB =
When CNB#3 is closed to a battery (key) voltage the
driver has activated the tiller (motion enabled).
-
OFF GND=
When CNB#3 is not connected to a battery (key) voltage
(or it is connected to GND), the driver has released the
tiller (motion disabled).
21) H&S CUTBACK
ON/OFF. This is the level of the CNB#4 digital input (Hard & Soft request).
With the H&S service is possible to turn the truck moving (at reduced speed)
only by acting the H&S switch, and the accelerator, without to let down the
tiller:
-
ON +VB =
When CNB#4 is closed to a battery (key) voltage, the
H&S request is Active.
-
OFF GND=
When CNB#4 is not connected to a battery (key) voltage
(or it is connected to GND), the H&S request is not active.
22) QUICK INVERSION
ON/OFF. This is the level of the CNB#7 digital input (the main function is
Quick Inversion request when the SET INPUT #4 is set BELLY):
-
ON GND=
This reading means the Quick Inversion request is active.
-
OFF +VB =
This reading means the Quick Inversion request is not
active
When QUICK INV LOGIC is set to OPTION#1 the quick inversion request is
active when CNB#7 is connected to a battery (key) voltage.
When QUICK INV LOGIC is set to OPTION#2 the quick inversion request is
active when CNB#7 is not connected to a battery (key) voltage.
This input CNB#7 has alternative functions depending on the setting of SET
INPUT #4. In these cases:
SET INPUT#4 is set BRAKE:
QUICK INVERSION reading becomes ON when the brake pedal switch
closes and connects the CNB#7 input to a key voltage.
SET INPUT#4 is set EX. HYDRO: