AE0ZP0EC - AC-0 SSL SENSORED - User Manual
Page - 67/100
QUICK INVERSION reading becomes ON when the Exclusive Hydro
Microswitch switch closes and connects the CNB#7 input to a key
voltage.
SET INPUT#4 is set OPTION #1:
QUICK INVERSION reading becomes ON when the Exclusive Hydro
Microswitch switch or the Belly switch closes and connects the CNB#7
input to a key voltage.
23) CUTBACK SWITCH 2
(Standard version only). ON/OFF. This is the level of the CNA#14 digital
input (When the MDI-PRC is not present, and SET INPUT #2 is set
PRESENT, this is the Speed Reduction #2 request):
-
ON GND =
When CNA#14 is not closed to a battery (key) voltage (or
connected to GND) the SR#2 request is active.
-
OFF +VB =
When CNA#14 is closed to a battery (key) voltage the
SR#2 request is not active.
This input CNA#14 has the alternative function of Inching Forward request
when the SET INPUT #2 is set to OPTION#1. Then the Inching Forward
request turns active (meanwhile this CUTBACK SWITCH 2 reading turns
ON) when the CNA#14 closes to a battery (key) voltage.
24) CUTBACK SWITCH 3
(Standard version only). ON/OFF. This is the level of the CNA#15 digital
input (When the MDI-PRC is not present, and the SET INPUT #3 is set
PRESENT, this is the Speed Reduction #3 request):
-
ON GND =
When CNA#15 is not closed to a battery (key) voltage (or
connected to GND) the SR#3 request is active.
-
OFF +VB =
When CNA#15 is closed to a battery (key) voltage the
SR#3 request is not active.
This input CNA#15 has the alternative function of Inching Backward request
when the SET INPUT #3 is set to OPTION#1. Then the Inching Backward
request turns active (meanwhile this CUTBACK SWITCH 3 reading turns
ON) when the CNA#15 closes to a battery (key) voltage.
25)
HANDBRAKE
ON/OFF. This is the level of the CNA#13 digital input (When the SET INPUT
#1 is set to Level 2 this is the Handbrake request):
-
ON GND =
When CNA#13 is not closed to a battery (key) voltage (or
connected to GND) the Handbrake request is active.
-
OFF +VB =
When CNA#13 is closed to a battery (key) voltage the
Handbrake request is not active.
This input CNA#13 has the alternative function of Speed Reduction #1
request when the SET INPUT #1 is set to Level 1. Then the Speed Reduction
#1 request turns active (meanwhile this HANDBRAKE reading turns ON)
when the CNA#13 closes to a battery (key) voltage.
9.6.2 Pump
1) BATTERY
VOLTAGE
Voltage value with 1 decimal digit. Battery voltage value measured at the key
input CNB#1.
2) MOTOR
VOLTAGE
Percentage value. It is the voltage generated by the inverter expressed in per
cent of the actual battery voltage. 100% means the sine wave width is close