Page - 68/100
AE0ZP0EC - AC-0 SSL SENSORED - User Manual
to the actual battery voltage; 0% means the sine wave width is null.
3) VOLTAGE
BOOSTER
Percentage value. It is the booster contribute to the voltage really supplied to
the motor expressed in per cent of the actual battery voltage. (Note: when
DC_LINK COMPENSATION is set ON, the VOLTAGE BOOSTER reading
will not match perfectly the booster setting because this latest one is
calculated respect to the nominal battery voltage; VOLTAGE BOOSTER is
expressed respect to the actual battery voltage).
4) FREQUENCY
Hz value with two decimal digit. This is the frequency of the sine waves the
inverter is supplying.
5) ENCODER
Hz value with two decimal digit. This is the speed of the motor measured with
the encoder and expressed in the same unit of the FREQUENCY reading.
6) SLIP
VALUE
Hz value with two decimal digit. This is the slip between the frequency and
the speed of the motor (SLIP VALUE = FREQUENCY-ENCODER).
7) CURRENT
RMS
Ampere value. Root Mean Square value of the line current in the motor.
8) BATTERY
CURRENT
Ampere value. This is a coarse calculation (not a measurement) of the
battery current.
9) BATTERY
CHARGE
Percentage value. It supplies the residual charge of the battery as a
percentage of the full charge level.
10) TEMPERATURE
°C value. This is the temperature of the inverter base plate. This temperature
is used for the HIGH TEMPERATURE alarm detection (see 11.1.7.1).
11) ACCELERATOR
From 0.0 V to 5.0 V. The voltage on the wiper of the accelerator (CPOT on
CNB#10) is halved inside the controller and then recorded on this reading.
That means the actual wiper voltage is in the range 0 to 10 V meanwhile the
corresponding ACCELERATOR reading is in the range 0.0 to 5.0 Vdc.
12) LIFTING SWITCH
ON/OFF. This is the level of the CNB#6 digital input (Lifting request):
-
ON +VB =
When CNB#6 is closed to a battery (key) voltage, the
Lifting request is active.
-
OFF GND=
When CNB#6 is not connected to a battery (key) voltage
(or it is connected to GND), the Lifting request is not
active.
13) 1ST SPEED SWITCH
ON/OFF. This is the level of the CNB#5 digital input (first speed request):
-
ON +VB = When CNB#5 is closed to a battery (key) voltage, the first
speed request is active.