AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
Page – 65/155
SET OPTIONS
Parameter
Allowable range
Description
EVP2 TYPE
(A)
NONE ÷ DIGITAL
This parameter defines the behavior of output EVP2 (
A23
).
NONE =
Output
A23
is not enabled.
ANALOG =
Output
A23
manages a PWM current-
controlled proportional valve.
DIGITAL =
Output
A23
manages an on/off valve.
EV1
(A)
ABSENT ÷ OPTION#2
This parameter defines the behavior of output EV1 (
A9
).
ABSENT =
Output
A9
is not enabled.
OPTION#1 =
Output
A9
manages an ON/OFF valve.
By default it is activated by the 1
st
speed command.
OPTION#2 =
free for future use.
EV2
(A)
ABSENT ÷ DIGITAL
This parameter defines the behavior of output EV2 (
A11
).
ABSENT =
Output
A11
is not enabled.
DIGITAL =
Output
A11
manages a PWM voltage-
controlled valve. The PWM frequency is 1 kHz and the
duty cycle depends on parameter PWM EV2
(ADJUSTMENTS list, paragraph 8.2.3).
EV3
(A)
ABSENT ÷ DIGITAL
This parameter defines the behavior of output EV3 (
A33
).
ABSENT =
Output
A33
is not enabled.
DIGITAL =
Output
A33
manages a PWM voltage-
controlled valve. The PWM frequency is 1 kHz and the
duty cycle depends on parameter PWM EV3
(ADJUSTMENTS list, paragraph 8.2.3).
EV4
(A)
ABSENT ÷ DIGITAL
This parameter defines the behavior of output EV4 (
A34
).
ABSENT =
Output
A34
is not enabled
.
DIGITAL =
Output
A34
manages an on/off valve.
EV5
(A)
ABSENT ÷ DIGITAL
This parameter defines the behavior of output EV5 (
A8
).
ABSENT =
Output
A8
is not enabled
.
DIGITAL =
Output
A8
manages an on/off valve.
HORN
(A)
ABSENT ÷ DIGITAL
It enables the control of output HORN
(
A26
).
ABSENT =
Output
A26
is not enabled.
DIGITAL =
Output
A26
manages an ON/OFF valve.
HIGH DYNAMIC
(T, TM, P, CO)
OFF ÷ ON
This parameter enables or disables the high-dynamic
function.
ON =
All acceleration and deceleration profiles set by
dedicated parameters are ignored and the controller
works always with maximum performance.
OFF =
Standard behavior.
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...