25
Dual DIP Switch Settings and Descriptions
(fig. 38A)
DIP Switch 1 and 2 – Gate Sequence
The default position for both DIP switch 1 and 2 is OFF.
The sequence of how the dual gates will close is deter-
mined by how these two switches are configured.
DIP Switch 3 – Gate Closing Delay
The default setting is OFF. If DIP switch 3 is set to the
ON position, it will add four seconds of delay before the
second gate closes. See examples below.
DIP Switch 4 – Closed Position Limits
This switch is used when setting the closed position lim-
its for each gate. The DIP switch is set to OFF when set-
ting the closed position limit for the first gate. The DIP
switch is set to ON when setting the closed position
limit for the second gate. See section “Setting the Gate’s
Closed Limit Position” on
page 27
.
To Set Open/Close Sequence and Times:
1 ON; 2 OFF; 3 OFF
First gate begins to open
two seconds before second
gate. Second gate begins to
close four seconds before
first gate.
1 OFF; 2 OFF
Factory setting for single
opener (actuator) operation.
Dual DIP
switches
Figure 38
DIP#6 DIP#7
Delay Time for
Auto-close
ON
ON
15 seconds
ON
OFF 30 seconds
OFF
ON
60 seconds
OFF*
OFF* 120 seconds
DIP#1
ON* – Soft start enabled
OFF – Soft start disabled
DIP#2
ON* – Gate moving audible warning enabled
OFF – Gate moving audible warning disabled
(
NOTE: obstruction alarm cannot be disabled
by putting DIP switch in OFF position
)
DIP#3
ON – Auto-close enabled
OFF* – Auto-close disabled (requires a signal to close)
DIP#4
ON – Push-to-open operation
OFF* – Pull-to-open operation
DIP#5
ON – D1 mode, constant pressure to operate gate
OFF* – B2 mode, momentary contact to operate gate
DIP#8
Not used
*Default factory setting
Figure 37
(Note: DIP switch 6 and 7 settings are only in effect
when DIP switch 3 in in ON position.)
NOTE:
Your Zareba Autmatic Gate Opener receiver is
compatible with built-in vehicle transmitter systems,
such as HomeLink. Refer to your vehicle owner’s manu-
al for instruction on how to program.