Safety distances for work in the vicinity of overhead power lines
Rated voltage
Safety clearance
< 1,000 V
1.0 m
1 kV-110 kV
3.0 m
110 kV-220 kV
4.0 m
220 kV-380 kV or if the rated voltage is not known
5.0 m
2.9 Safety instructions for access steps with platform
WARNING
Injury to persons
Improper assembly, dismantling, operation and maintenance of the product may lead to
severe injury.
• Mount all supplied ballast weights and take the prescribed stability measures.
• Never use the product outdoors without ballast weights.
3 Overview
3.1 Scope of delivery
The scope of delivery is customer-specific and may vary according to each order.
• Before you start assembling the product, check that all components listed in the order
confirmation and delivery note are included and free of defects.
• Use only original parts in good working condition to assemble the product.
• Contact the manufacturer if parts are missing or damaged.
• Observe the type plate.
3.2 Options
The following options are available for adapting the product to structural conditions:
• Storage tray
• Storage and retrieval tray
• Swing door
• Railing storage hook
3.3 Accessories
Additional accessories are available directly from ZARGES.