3.5.11 Safety rails
U-shaped rail
Order no.
43495
Material
Aluminium
Size (W x D)
mm
750 x 540
Weight
kg
2.8
Guardrail
Order no.
43493
43490 (with U-shaped rail
43495)
Material
Aluminium / concrete
Aluminium / concrete
Size (W x D)
mm
1500 x 1300
Weight (incl. concrete panels)
kg
132
135
4 Installation
4.1 Safety instructions
• Ladder systems must always be installed vertically.
• If you intend to install the wall brackets using a screw anchor system, only use ones
that have been approved by the building control authority. The company carrying out
installation is responsible for the work and must examine the masonry thoroughly.
If you are unsure of anything, contact an expert in structural engineering or a technical
consultant from the manufacturer of the screw anchors (mandatory in accordance
with DIN 14094-1). The attachment hardware of each wall bracket must be able to
withstand a total pull-out force of ≥3 kN and, when used in combination with a fall
arrester system (e.g. the ZARGES ZAST fall arrester system), an impact force of ≥6 kN.
Screw anchors are not included in the scope of delivery.
• Where it is necessary to cut components to size, this work must be performed by
specialist personnel on-site.
– Deburr all edges.
– Restore anti-corrosion protection.
38
Summary of Contents for 41286
Page 61: ...4 3 B2 1 2 13 17 5 Nm 2 2 1 M8 M8 M8x65 2 1 3 17 5 Nm 4 3 B3 1 2 1 3 61...
Page 63: ...4 3 B5 1 2 M8 M8 17 5 Nm M8 M8 13 2x 17 5 Nm 1 1 2 2 4 3 B6 1 2 M8 M8 17 5 Nm 1 2 13 2x A19 63...
Page 64: ...4 3 B7 1 M8 M8 17 5 Nm 2 13 2x...
Page 68: ...4 3 B12 1 2 3 1 2 13 17 5 Nm 0...
Page 72: ...4 3 C8 13 2x 1 2 10x 1 2 3 4 4 3 C7 13 2x 1 2 1 1 2 4 3 17 5 Nm 5 5 6 17 5 Nm...
Page 73: ...4 3 C9 10 73...