7
Attaching inspection stickers
6
Attaching inspection stickers
ZARGES service lifts must be provided with inspection stickers the next time
annual service is carried out, but no later than April 2017.
X
Have the inspection stickers filled out according to the available documen-
tation by an expert the first time they are attached:
à
Date of initial commissioning
à
Date of last servicing
à
Date of last inspection
à
Date of next servicing (faces upward)
X
Attach the inspection stickers to the inspection sticker strip (item number
35104380000) in the intended location (see figure).
X
Attach the inspection sticker strip in the intended location next to the type
plate in the service lift.
7
General inspection steps
7.1 Checking sealing
Before each use by the operating personnel, ensure that:
X
The seal over the opening for overload setting is in place and not
broken (see Chapter 5).
X
The seal at the control box is in place and not broken (see Chap-
ter 5).
If the seal is not in place or is broken:
X
Decommission the service lift immediately.
X
Attach a corresponding sign at the main switch of the service lift.
X
Have the respective component inspected and repaired by the manufacturer or a qualified person who has
been trained in this task.
The inspections and results must be documented in the inspection record immediately after the inspection.
X
Tick the "Seals" field after the inspection has been carried out.
X
If the inspection failed, tick the "Out of service" field.
X
Enter any special items of note in the "Notes" field.
7.2 Inspecting inspection stickers
X
Before each use by the operating personnel, ensure that:
à
The date of the initial commissioning is located on the sticker.
à
The date of the next servicing is located on the sticker and has not
expired.
X
Observe national regulations and, if necessary, ensure that the date of
the inspection by the expert is located on the sticker and has not expired.
In case of faults, malfunctions, damage, missing or expired inspection stick-
ers or other defects:
X
Decommission the service lift immediately.
X
Attach a corresponding sign at the main switch of the service lift.
X
Get caught up on expired inspection by an expert immediately.
X
Record the issue separately, report it to the manufacturer and operator
and have it examined by a qualified person who has been trained by
ZARGES.
The inspections and results must be documented in the inspection record immediately after the inspection.
X
Tick the "Stickers" field after the inspection has been carried out.
X
If the inspection failed, tick the "Out of service" field.
X
Enter any special items of note in the "Notes" field.