ZBA Inc.
27
Thermal and Centering
If a bar code is not within the predefined window, it will not be decoded or output by the imager. If centering is turned on by scanning
Centering On
, the
imager only reads codes that intersect the centering window you specify using the
Top
,
Bottom
,
Left
, or
Right
bar codes. Scan
Centering On
, then scan
one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering
window using digits on the inside back cover of this manual. Scan
Save
. Default Centering = 40% for Top and Left, 60% for Bottom and Right.
Centering On
Top of Centering Window
Left of Centering Window
*Centering Off
Bottom of Centering Window
Right of Centering Window
Summary of Contents for ZB-3062
Page 1: ...ZBA Inc 1 ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 www zbausa com...
Page 56: ...ZBA Inc 56...
Page 80: ...ZBA Inc 80...
Page 83: ...ZBA Inc 83 QR Code DataMatrix Aztec MaxiCode...
Page 87: ...ZBA Inc 87 13 ASCII Code Table...
Page 88: ...ZBA Inc 88 14 OCR Prog Chart...
Page 89: ...ZBA Inc 89 15 Program Chart...