ZBA Inc.
31
Output Sequence
Require Output Sequence
When an output sequence is
Required
, all output data must conform to an edited sequence or the imager will not transmit the output data to the host device.
When it’s
On/Not Required
, the imager will attempt to get the output data to conform to an edited sequence, but if it cannot, the imager transmits all output
data to the host device as is. When the output sequence is
Off
, the bar code data is output to the host as the imager decodes it.
Note:
This selection is unavailable when the Multiple Symbols Selection is turned on.
Output Sequence Editor
Enter Sequence
Default Sequence
Require Output Sequence
Required
On/Not Required
*Off
Multiple Symbols
When this programming selection is turned
On
, it allows you to read multiple symbols when the trigger is activated. If you press and hold the trigger, aiming
the Imager at a series of symbols, it reads unique symbols once, beeping (if
turned on) for each read. The imager attempts to find and decode new symbols as long as the trigger is activated. When this programming selection is turned
Off
, the Imager will only read the symbol closest to the aiming beam.
No Read
With No Read turned
On
, the Imager notifies you if a code cannot be read. If using a Quick*View Scan Data Window, an “NR” appears when a code cannot
be read. If No Read is turned
Off
, the “NR” will not appear.
Multiple Symbols
Note
: This feature does not
work when the Imager is in
Low Power mode.
On
*Off
No Read
On
*Off
Summary of Contents for ZB-3062
Page 1: ...ZBA Inc 1 ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 www zbausa com...
Page 56: ...ZBA Inc 56...
Page 80: ...ZBA Inc 80...
Page 83: ...ZBA Inc 83 QR Code DataMatrix Aztec MaxiCode...
Page 87: ...ZBA Inc 87 13 ASCII Code Table...
Page 88: ...ZBA Inc 88 14 OCR Prog Chart...
Page 89: ...ZBA Inc 89 15 Program Chart...