background image

 

 

ZBA Inc

.

 

 
 

                  V1.04                                                               

ZBA, Inc.

                                 Page 9 of 25            

94 Old Camplain Road    Hillsborough, NJ 08844 

Ph: 908-359-2070   Fax: 908-595-0909 

Web: http://www.zbausa.com/ 

 

 

        

RT01  

 

ACK/NAK response time 300ms 

 

RT02  

 

ACK/NAK response time 2s 

 

RT03  

 

ACK/NAK response time 500ms 

 

RT04  

 

ACK/NAK response time 3s 

 

RT05  

 

ACK/NAK response time 1s 

 

RT06  

 

ACK/NAK response time 5s 

 

RT07  

 

ACK/NAK response time infinity 

 

SB01  

 

1 stop bit 

 

SB02  

 

2 stop bit 

 

DB07  

 

7 data bit 

 

DB08  

 

8 data bit 

 

DT11  

 

RS-232 message terminator—none

 

 

 

DT12  

 

RS-232 message terminator—CR/LF

 

 

 

DT13  

 

RS-232 message terminator—CR 

 

DT14  

 

RS-232 message terminator—LF 

 

DT15  

 

RS-232 message terminator—H tab 

 

DT16  

 

RS-232 message terminator—STX/ETX 

 

DT17  

 

RS-232 message terminator—EOT 

 

 

Summary of Contents for ZLIM-211

Page 1: ...ZBA Inc V1 04 ZBA Inc Page 1 of 25 94 Old Camplain Road Hillsborough NJ 08844 Ph 908 359 2070 Fax 908 595 0909 Web http www zbausa com ZLIM 211 Programming barcode manual V1 04...

Page 2: ...ry terminals time and attendance terminals ski pass automated sorting machines and more Factory default setting RS 232 communication Default Baud rate 9600 Parity None Data Bits 8 Stop Bit 1 RTS CTS o...

Page 3: ...fier code O LED Beep transmission Default Led Beep Before transmission On Default data transmit format Code Message format EAN 13 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 EAN 8 D1 D2 D3 D4 D5 D6 D7...

Page 4: ...ing Barcode Value Description Remark Start Of Configuration End Of Configuration Reset return to factory default Abort exit programming mode no update Display firmware version GR01 Medium beeper tone...

Page 5: ...transmission Use this bar code to indicate a good read after a bar code has been successfully decoded LB01 Led Beep before transmission Use this bar code to indicate a good read after successfully tra...

Page 6: ...mitted but the successive transmission of the same bar code is not allowed when the trigger switch is pressed again SM04 Alternate mode This scanner will light up when press the scanner trigger switch...

Page 7: ...mode and Alternate mode use LS01 Laser sleep time 5 second LS02 Laser sleep time 10 second LS03 Laser sleep time 15 second LS04 Laser sleep time 20 second LS05 Laser sleep time 30 second LS06 Laser s...

Page 8: ...e 19200 BR02 Baud Rate 9600 BR03 Baud Rate 4800 BR04 Baud Rate 2400 BR05 Baud Rate 1200 BR08 Baud Rate 57600 BR09 Baud Rate 115200 HP01 None handshaking HP02 ACK NAK HP03 Xon Xoff HP04 RTS CTS PB01 Ev...

Page 9: ...ACK NAK response time 3s RT05 ACK NAK response time 1s RT06 ACK NAK response time 5s RT07 ACK NAK response time infinity SB01 1 stop bit SB02 2 stop bit DB07 7 data bit DB08 8 data bit DT11 RS 232 mes...

Page 10: ...ansmission A B C D CB07 Codabar start stop character transmission DC1 DC4 CB08 Codabar start stop character transmission a t b n c d e CB09 Codabar maximum length setting CB10 Codabar minimum length s...

Page 11: ...data redundant check 1 DC02 Code 39 data redundant check 2 3901 Standard code 39 3902 FULL ASCII code 39 3903 Code 39 start stop character transmission 3904 Code 39 start stop character without transm...

Page 12: ...enable RD08 Code 93 disable DC30 Code 93 data redundant check off DC31 Code 93 data redundant check 1 DC32 Code 93 data redundant check 2 9301 Code 93 maximum length setting 9302 Code 93 minimum lengt...

Page 13: ...NC2 concatenation disable 1803 No check character 1804 Calculate but not transmitt 1805 Calculate and transmitt 1806 Code 128 maximum length setting 1807 Code 128 minimum length setting ALL Chinese po...

Page 14: ...minimum length setting MS03 MSI Plessy double check digit calculate but not transmit MS04 MSI Plessy double check digit without calculate and transmit MS05 MSI Plessy double check digit calculate but...

Page 15: ...length is greater than 10 character 1106 Disable verification 1107 Code 11 check digit transmitted 1108 Code 11 check digit not transmitted ITF 2 of 5 RC04 ITF 2 of 5 enable RD04 ITF 2 of 5 disable R...

Page 16: ...2 of 5 one Fixed length setting IT07 ITF 2 of 5 two Fixed length setting SET Save setting to confirm for need to reading full ASCII Table confirm use UPC EAN JAN RC11 EAN convert toISSN ISBN enable R...

Page 17: ...le UE15 Force UPC A to EAN 13 format enable UE16 Force UPC A to EAN 13 format disable UE17 Transmit UPC A check digit enable UE18 Transmit UPC A check digit disable UE19 Transmit UPC E leading charact...

Page 18: ...out separator UE32 EAN UPC addon none mandatory UE44 force EAN 8 to EAN 13 format enable UE45 force EAN 8 to EAN 13 format disable UE60 EAN 13 first 0 can transmitted UE61 EAN 13 first 0 can t transmi...

Page 19: ...dustrial 2 of 5 Identifier code setting CI16 Code 11 Identifier code setting CI17 Standard 2 of 5 Identifier code setting CP11 Add code length as header enable all barcode CP12 Add code length as head...

Page 20: ...y 0 ms IM02 Inter message delay 100 ms IM03 Inter message delay 500 ms IM04 Inter message delay 1000 ms IS00 Disable identifier code IS01 Enable identifier code table as ZEBEX standard ALL SET Save se...

Page 21: ...f 5 code disable D051 STD 2 of 5 code maximum length setting D052 STD 2 of 5 code minimum length setting Code 39 Full ASCII Table Code 39 ASCII Full ASCII Code 39 value Hex code Code 39 ASCII Code 39...

Page 22: ...359 2070 Fax 908 595 0909 Web http www zbausa com LF J 0A EN Y 19 VT K 0B SUB Z 1A FF L 0C ESC A 1B CR M 0D FS B 1C SO N 0E GS C 1D RS D 1E 2D US E 1F 2E SP SP 20 2F A 21 0 0 30 B 22 1 1 31 C 23 2 2 3...

Page 23: ...Ph 908 359 2070 Fax 908 595 0909 Web http www zbausa com K 2B Z 3A L 2C F 3B G 3C K K 4B H 3D L L 4C I 3E M M 4D J 3F N N 4E V 40 O O 4F A A 41 P P 50 B B 42 Q Q 51 C C 43 R R 52 D D 44 S S 53 E E 45...

Page 24: ...359 2070 Fax 908 595 0909 Web http www zbausa com Z Z 5A i I 69 K 5B J J 6A L 5C K K 6B M 5D L L 6C N 5E M M 6D _ O 5F n N 6E W 60 O O 6F a A 61 P P 70 b B 62 Q Q 71 c C 63 R R 72 d D 64 s S 73 e E 65...

Page 25: ...ZBA Inc V1 04 ZBA Inc Page 25 of 25 94 Old Camplain Road Hillsborough NJ 08844 Ph 908 359 2070 Fax 908 595 0909 Web http www zbausa com P 7B DEL T 7F...