ZBA Inc
.
ZBA, Inc.
94 Old Camplain Road Hillsborough, NJ 08844
Ph: 908-359-2070 Fax: 908-595-0909
Web: http://www.zbausa.com/
a)
External processor to the Zigbee nodule: (check local
MAC
address)
55 AA 00 01 0D 41 54 2B 4C 45 58 54 41 44 44 52 3F 0D
Header Package Type
Seq. #
Data len. Valid data
55 AA
00
01
0D
41 54 2B 4C 45 58 54 41 44 44 52 3F 0D
b)
Zigbee
modules response
to the external processor: (packet reception response)
55 AA 20 01 06 0D 0A 4F 4B 0D 0A
Header Package Type
Seq. #
Data len. Valid data
55 AA
20
01
0D
0D 0A 4F 4B 0D 0A
c)
The local
MAC
address
Zigbee module
[MAC aLETXADDR:0000000000001211]
55 AA 01 01 1E 0D 0A 2B 4C 45 58 54 41 44 44 52 3A 30 30 30 30 30 30 30 30 30 30 30 30 31 32 31 31
0D 0A
Header Package Type
Seq. #
Data len. Valid data
55 AA
01
01
1E
0D 0A 2B 4C 45 58 54 41 44 44 52 3A
30 30 30 30 30 30 30 30 30 30 30 30 31
32 31 31 0D 0A
10.3
Instruction 1: MAC address of the local inquiry
Command
Response
Parameters
AT+LEXTADDR?\r
\r\n+LEXTADDR:<eaddr>\r\n
eaddr:
64-bit
extended
MAC
address
Note: In the configuration state, it is also a "check the local
MAC
address" command; but in the configuration state
to send the command without adding header, you can directly only in work mode, and when the point to point mode,
only need to increase the header.
10.4
Instruction 2: Query a short address local network
Command
Response
Parameters
AT+LSHORTADDR?\r
\r\n+LSHORTADDR:<saddr>\r\n
saddr:
16-bit
short address
10.5
Instruction 3: MAC address of the remote query