background image

Preface 

 
The CPE-2(x) series modular 802.11b wireless 
radio solution was designed to meet the growing 
needs of The ISP, System Integrator and other 
professional developers. The CPE-2(x) series 
product is intended for long distance point to 
point communications over the wireless medium. 
This manual will demonstrate how the 
equipment is to be used in a safe an lawful 
manner. 

 
 

 

** 

IMPORTANT

 ** 

 
The installation of the PCMCIA module into an 
enclosure requires that the integrator label the 
outside of the enclosure with the FCC ID 
printed on the module. 
 
Changes or modifications not expressly 
approved by Zcomax Technologies, Inc. may 
void the user’s authority to operate the 
equipment. 
 
“Note: This equipment has been tested and 
found to comply with the limits for a Class A 
digital device, pursuant to Part 15 of the FCC 
Rules. These limits are designed to provide 
reasonable protection against harmful 
interference when the equipment is operated in 
a commercial environment. This equipment 
generates uses and can radiate frequency 
energy and, if not installed and used in 
accordance with the instruction manual, may 
cause harmful interference to radio 
communications. Operation of this equipment in 
a residential area is likely to cause harmful 
interference in which case the user will be 
required to correct the interference at his own 
expense”. 
 
 
 
 
 

ƒ

 

HEAT

 

o

  The product should be situated 

away from heat sources such as 
radiators, heat registers, stoves, or 
other appliances (including 
amplifiers) that produce heat. 

 

ƒ

 

OUTDOOR ANTENNA GROUNDING 

o

  Be sure the product is grounded 

so as to provide some protection 
against voltage surges and built 
up static charges. 

o

  Section 810 of the National 

Electrical Code (NEC), 
ANSI/NFPA No. 70-1990, 
provides information with respect 
to proper grounding of the mast 
and supporting structure, 
grounding of the lead-in wire to 
an antenna-discharge unit, size 
of grounding conductors, 
location of antenna-discharge 
unit, connection to ground 
electrodes, and requirements for 
the grounding electrode.  

o

 

Note to Installer: This 
reminder is provided to call 
the installer’s attention to 
article 820-40 of the NEC that 
provide guidelines for proper 
grounding and in particular, 
specifies that the cable ground 
should be connected to the 
grounding system of the 
building, as close to the point 
of cable entry as practical. 

 

ƒ

 

DAMAGE REQUIRING SERVICE 

o

  This product should be serviced 

by qualified service personnel 
when: 

ƒ

  The power supply cord or 

plug has been damaged, 
or 

ƒ

  An object or liquid has 

entered into the product, 
or 

ƒ

  The product does not 

operate normally or 
exhibits a marked 
changed in performance, 
or 

ƒ

  The product has been 

dropped, or the enclosure 
has been damaged. 

 
This product should only be installed 
by a qualified professional.
 

 

The CPE device

 

MUST

 

be installed to 

provide a separation distance

 

of at 

least 35cm

 

from all persons and must 

not be collocated or operating in 

FCC

 

S

TATEMENT

 

I

MPORTANT 

S

AFETY 

I

NSTRUCTIONS

 

Summary of Contents for AIRRUNNER CPE-2 Series

Page 1: ...CPE 25 x Series OEM INSTALLERS QUICK START GUIDE A I R R U N N E R C P E ...

Page 2: ... situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat OUTDOOR ANTENNA GROUNDING o Be sure the product is grounded so as to provide some protection against voltage surges and built up static charges o Section 810 of the National Electrical Code NEC ANSI NFPA No 70 1990 provides information with respect to proper grounding...

Page 3: ...er needed to establish a reliable connection Configuration Connections o The PCMCIA Card is inserted into SBC The PCMCIA rails are keyed so as to avert a wrong insertion method o The Antenna feed line is terminated with an MMCX reverse polarity plug that is used to connect to the PCMCIA s primary antenna jack Jack closets to the PCMCIA s LEDs Mounting o The antenna can be mounted with the use four...

Page 4: ...CD ROM drive Run SETUP EXE from the CD s root directory b Follow the on screen prompts to install the software on to your system 3 Connect All Cables Connect cables as follows a Insert the Category 5 cable to the Power Injector port marked NETWORK Insert the other end of the cable to an Ethernet hub b Insert the CPE 250HP s RJ 45 connector to the Power Injector port marked CPE c Insert the AC adap...

Page 5: ... mark next to NAT IP Sharing through this port o Click on the Close button to close this pop up window p You are now returned to the original IP Address tab window Click on the SETUP button BELOW the WAN port radio buttons WAN on WLA WAN on ETH to setup the LAN port q A new windows pops over the current windows Enter the Router s LAN port IP Address and netmask r If you would like to use the built...

Page 6: ...ger Software Default password default Web based Management Point your browser at the Product s IP address default IP address 192 168 1 1 Default password default Telnet Open a Telnet session at the product s IP address default IP address 192 168 1 1 Default password default Copyright 2002 Zcomax Technologies Inc All rights reserved P N QSG15 130 Rev 1 3 Zcomax and AirRunner are registered trademar...

Reviews: