ZPrinter
®
450 Hardware Manual
Printer Maintenance
50
All Rights Reserved
10/2/07
5. Extract two full syringes of binder (to remove any air in the line) and empty the binder into a waste
receptacle. Use a paper towel to catch any binder that may drip out of the tubing when you remove the
fitting from the septum to empty the syringe.
6. Extract one last full syringe of binder and slowly squeeze ¾ of the binder back through the line. This
will assure that no air bubbles remain in the binder line. Dispose of any remaining binder in the syringe.
7. Clean the pogo pins and Printhead contacts with an alcohol swab and reinsert the Printhead.
8. Close the carriage cover. The Auto Alignment will run before your next print job to realign the Print-
heads.
6.9 Printer Storage Preparation
It is recommended that you leave your ZPrinter 450 turned on during idle times so it can routinely service
the print heads and exercise the moving components. However, if you choose to leave the printer turned
off for more than 4 months, before using the machine again, you will need to pull a syringe of binder
through the lines (to remove any air), and replace the printheads because they will be dried out.
Contact your local Service Provider, or an authorized Z Corporation representative, to discuss any con-
cerns before storing your printer.