User’s Manual 1PH HYD3000-HYD6000-ZP1
Rev. 1.0 01/09/2023
Identification: MD-AL-GI-00
Rev. 1.1 of 27/01/2023 - Application: GID
59/193
6.4.
Photovoltaic connection
Recommended specifications for DC input cables
Cross-sectional area (mm
2
/ AWG)
Outer diameter of cable (mm
2
)
Range
Recommended value
4.0-6.0 / 11-9
4.0 / 11
4.5~7.8
Procedure:
Step 1:
Prepare the positive and negative photovoltaic cables.
Figure 32 – Preparing the positive and negative photovoltaic cables
Step 2:
Insert the crimped positive and negative cables into the corresponding photovoltaic connectors.
Figure 33 – Preparing the positive and negative photovoltaic connectors
Step 3:
Make sure that the DC voltage of each photovoltaic string is less than 550V DC and that the polarities of
the photovoltaic cables are correct. Insert the positive and negative connectors in the 1PH HYD3000-HYD6000-
ZP1 inverter until you hear a “click” sound, as show in below Figure.